Dual Energy Method for Breast Imaging: A Simulation Study
المؤلفون المشاركون
Fountos, George P.
Koukou, V.
Martini, N.
Sotiropoulou, P.
Fountzoula, C.
Nikiforidis, G.
Kandarakis, Ioannis S.
Michail, Christos M.
Kalyvas, Nektarios E.
المصدر
Computational and Mathematical Methods in Medicine
العدد
المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-8، 8ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2015-07-13
دولة النشر
مصر
عدد الصفحات
8
التخصصات الرئيسية
الملخص EN
Dual energy methods can suppress the contrast between adipose and glandular tissues in the breast and therefore enhance the visibility of calcifications.
In this study, a dual energy method based on analytical modeling was developed for the detection of minimum microcalcification thickness.
To this aim, a modified radiographic X-ray unit was considered, in order to overcome the limited kVp range of mammographic units used in previous DE studies, combined with a high resolution CMOS sensor (pixel size of 22.5 μm) for improved resolution.
Various filter materials were examined based on their K-absorption edge.
Hydroxyapatite (HAp) was used to simulate microcalcifications.
The contrast to noise ratio (CNRtc) of the subtracted images was calculated for both monoenergetic and polyenergetic X-ray beams.
The optimum monoenergetic pair was 23/58 keV for the low and high energy, respectively, resulting in a minimum detectable microcalcification thickness of 100 μm.
In the polyenergetic X-ray study, the optimal spectral combination was 40/70 kVp filtered with 100 μm cadmium and 1000 μm copper, respectively.
In this case, the minimum detectable microcalcification thickness was 150 μm.
The proposed dual energy method provides improved microcalcification detectability in breast imaging with mean glandular dose values within acceptable levels.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Koukou, V.& Martini, N.& Michail, Christos M.& Sotiropoulou, P.& Fountzoula, C.& Kalyvas, Nektarios E.…[et al.]. 2015. Dual Energy Method for Breast Imaging: A Simulation Study. Computational and Mathematical Methods in Medicine،Vol. 2015, no. 2015, pp.1-8.
https://search.emarefa.net/detail/BIM-1057940
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Koukou, V.…[et al.]. Dual Energy Method for Breast Imaging: A Simulation Study. Computational and Mathematical Methods in Medicine No. 2015 (2015), pp.1-8.
https://search.emarefa.net/detail/BIM-1057940
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Koukou, V.& Martini, N.& Michail, Christos M.& Sotiropoulou, P.& Fountzoula, C.& Kalyvas, Nektarios E.…[et al.]. Dual Energy Method for Breast Imaging: A Simulation Study. Computational and Mathematical Methods in Medicine. 2015. Vol. 2015, no. 2015, pp.1-8.
https://search.emarefa.net/detail/BIM-1057940
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1057940
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر