Few-View Prereconstruction Guided Tube Current Modulation Strategy Based on the Signal-to-Noise Ratio of the Sinogram
المؤلفون المشاركون
Chang, Ming
Xiao, Yongshun
Chen, Zhiqiang
المصدر
Computational and Mathematical Methods in Medicine
العدد
المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-8، 8ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2015-05-18
دولة النشر
مصر
عدد الصفحات
8
التخصصات الرئيسية
الملخص EN
The radiation dose reduction without sacrificing the image quality as an important issue has raised the attention of CT manufacturers and different automatic exposure control (AEC) strategies have been adopted in their products.
In this paper, we focus on the strategy of tube current modulation.
It is deduced based on the signal-to-noise (SNR) of the sinogram.
The main idea behind the proposed modulation strategy is to keep the SNR of the sinogram proximately invariable using the few-view reconstruction as a good reference because it directly affects the noise level of the reconstructions.
The numerical experiment results demonstrate that, compared with constant tube current, the noise distribution is more uniform and the SNR and CNR of the reconstruction are better when the proposed strategy is applied.
Furthermore it has the potential to distinguish the low-contrast target and to reduce the radiation dose.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Chang, Ming& Xiao, Yongshun& Chen, Zhiqiang. 2015. Few-View Prereconstruction Guided Tube Current Modulation Strategy Based on the Signal-to-Noise Ratio of the Sinogram. Computational and Mathematical Methods in Medicine،Vol. 2015, no. 2015, pp.1-8.
https://search.emarefa.net/detail/BIM-1058031
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Chang, Ming…[et al.]. Few-View Prereconstruction Guided Tube Current Modulation Strategy Based on the Signal-to-Noise Ratio of the Sinogram. Computational and Mathematical Methods in Medicine No. 2015 (2015), pp.1-8.
https://search.emarefa.net/detail/BIM-1058031
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Chang, Ming& Xiao, Yongshun& Chen, Zhiqiang. Few-View Prereconstruction Guided Tube Current Modulation Strategy Based on the Signal-to-Noise Ratio of the Sinogram. Computational and Mathematical Methods in Medicine. 2015. Vol. 2015, no. 2015, pp.1-8.
https://search.emarefa.net/detail/BIM-1058031
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1058031
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر