Estimating the Radiation Dose to the Fetus in Prophylactic Internal Iliac Artery Balloon Occlusion: Three Cases
المؤلفون المشاركون
Kai, Kentaro
Hamada, Tomohiro
Yuge, Akitoshi
Kiyosue, Hiro
Nishida, Yoshihiro
Narahara, Hisashi
Nasu, Kaei
المصدر
Case Reports in Obstetrics and Gynecology
العدد
المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-7، 7ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2015-06-09
دولة النشر
مصر
عدد الصفحات
7
التخصصات الرئيسية
الملخص EN
Background.
Although radiation exposure is of great concern to expecting patients, little information is available on the fetal radiation dose associated with prophylactic internal iliac artery balloon occlusion (IIABO).
Here we estimated the fetal radiation dose associated with prophylactic IIABO in Caesarean section (CS).
Cases.
We report our experience with the IIABO procedure in three consecutive patients with suspected placenta previa/accreta.
Fetal radiation dose measurements were conducted prior to each CS by using an anthropomorphic phantom.
Based on the simulated value, we calculated the fetal radiation dose as the absorbed dose.
We found that the fetal radiation doses ranged from 12.88 to 31.6 mGy.
The fetal radiation dose during the prophylactic IIABOs did not exceed 50 mGy.
Conclusion.
The IIABO procedure could result in a very small increase in the risk of harmful effects to the fetus.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Kai, Kentaro& Hamada, Tomohiro& Yuge, Akitoshi& Kiyosue, Hiro& Nishida, Yoshihiro& Nasu, Kaei…[et al.]. 2015. Estimating the Radiation Dose to the Fetus in Prophylactic Internal Iliac Artery Balloon Occlusion: Three Cases. Case Reports in Obstetrics and Gynecology،Vol. 2015, no. 2015, pp.1-7.
https://search.emarefa.net/detail/BIM-1059092
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Kai, Kentaro…[et al.]. Estimating the Radiation Dose to the Fetus in Prophylactic Internal Iliac Artery Balloon Occlusion: Three Cases. Case Reports in Obstetrics and Gynecology No. 2015 (2015), pp.1-7.
https://search.emarefa.net/detail/BIM-1059092
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Kai, Kentaro& Hamada, Tomohiro& Yuge, Akitoshi& Kiyosue, Hiro& Nishida, Yoshihiro& Nasu, Kaei…[et al.]. Estimating the Radiation Dose to the Fetus in Prophylactic Internal Iliac Artery Balloon Occlusion: Three Cases. Case Reports in Obstetrics and Gynecology. 2015. Vol. 2015, no. 2015, pp.1-7.
https://search.emarefa.net/detail/BIM-1059092
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1059092
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر