Essure Microinsert Abdominal Migration after Hysteroscopic Tubal Sterilization of an Appropriately Placed Essure Device: Dual Case Reports and Review of the Literature

المؤلفون المشاركون

Rezai, Shadi
LaBine, Meghan
Gomez Roberts, Hunter Azdel
Lora Alcantara, Isamarie
Henderson, Cassandra E.
Elmadjian, Malvina
Nuritdinova, Dilfuza

المصدر

Case Reports in Obstetrics and Gynecology

العدد

المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-5، 5ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2015-11-18

دولة النشر

مصر

عدد الصفحات

5

التخصصات الرئيسية

الأمراض

الملخص EN

Background.

The Essure device is a method of permanent sterilization widely used in the US that has proven to be safe and effective in most cases.

However, there have been reports of device migration that have led to failed tubal occlusion as well as several other serious complications resulting from the presence of the device in the abdominal cavity.

Case.

This paper represents two cases of failed tubal occlusion by an appropriately placed Essure device without signs or symptoms of further complications related to device migration.

Conclusion.

Although there have only been 13 reported cases of abdominal device migration since November 2014, this case indicates that the actual number may be higher than reported since it is possible for migration to occur without additional complications.

In the majority of reported cases of abdominal migration a major complication requiring surgical correction occurred, such as adhesions, small bowel obstruction, bowel perforation, or persistent pelvic pain.

To avoid these complications it is recommended that migrating implants be removed; however, this case also represents an example of when a migrating device may remain in situ in an asymptomatic patient.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Rezai, Shadi& LaBine, Meghan& Gomez Roberts, Hunter Azdel& Lora Alcantara, Isamarie& Henderson, Cassandra E.& Elmadjian, Malvina…[et al.]. 2015. Essure Microinsert Abdominal Migration after Hysteroscopic Tubal Sterilization of an Appropriately Placed Essure Device: Dual Case Reports and Review of the Literature. Case Reports in Obstetrics and Gynecology،Vol. 2015, no. 2015, pp.1-5.
https://search.emarefa.net/detail/BIM-1059129

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Rezai, Shadi…[et al.]. Essure Microinsert Abdominal Migration after Hysteroscopic Tubal Sterilization of an Appropriately Placed Essure Device: Dual Case Reports and Review of the Literature. Case Reports in Obstetrics and Gynecology No. 2015 (2015), pp.1-5.
https://search.emarefa.net/detail/BIM-1059129

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Rezai, Shadi& LaBine, Meghan& Gomez Roberts, Hunter Azdel& Lora Alcantara, Isamarie& Henderson, Cassandra E.& Elmadjian, Malvina…[et al.]. Essure Microinsert Abdominal Migration after Hysteroscopic Tubal Sterilization of an Appropriately Placed Essure Device: Dual Case Reports and Review of the Literature. Case Reports in Obstetrics and Gynecology. 2015. Vol. 2015, no. 2015, pp.1-5.
https://search.emarefa.net/detail/BIM-1059129

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1059129