![](/images/graphics-bg.png)
An Optimized High Throughput Clean-Up Method Using Mixed-Mode SPE Plate for the Analysis of Free Arachidonic Acid in Plasma by LC-MSMS
المؤلفون المشاركون
Wang, Wan
Qin, Suzi
Li, Linsen
Chen, Xiaohua
Wang, Qunjie
Wei, Junfu
المصدر
International Journal of Analytical Chemistry
العدد
المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-6، 6ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2015-03-19
دولة النشر
مصر
عدد الصفحات
6
التخصصات الرئيسية
الملخص EN
A high throughput sample preparation method was developed utilizing mixed-mode solid phase extraction (SPE) in 96-well plate format for the determination of free arachidonic acid in plasma by LC-MS/MS.
Plasma was mixed with 3% aqueous ammonia and loaded into each well of 96-well plate.
After washing with water and methanol sequentially, 3% of formic acid in acetonitrile was used to elute arachidonic acid.
The collected fraction was injected onto a reversed phase column at 30°C with mobile phase of acetonitrile/water (70 : 30, v/v) and detected by LC-MS/MS coupled with electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode.
The calibration curve ranged from 10 to 2500 ng/mL with sufficient linearity (r 2 = 0.9999).
The recoveries were in the range of 99.38% to 103.21% with RSD less than 6%.
The limit of detection is 3 ng/mL.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Wang, Wan& Qin, Suzi& Li, Linsen& Chen, Xiaohua& Wang, Qunjie& Wei, Junfu. 2015. An Optimized High Throughput Clean-Up Method Using Mixed-Mode SPE Plate for the Analysis of Free Arachidonic Acid in Plasma by LC-MSMS. International Journal of Analytical Chemistry،Vol. 2015, no. 2015, pp.1-6.
https://search.emarefa.net/detail/BIM-1064423
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Wang, Wan…[et al.]. An Optimized High Throughput Clean-Up Method Using Mixed-Mode SPE Plate for the Analysis of Free Arachidonic Acid in Plasma by LC-MSMS. International Journal of Analytical Chemistry No. 2015 (2015), pp.1-6.
https://search.emarefa.net/detail/BIM-1064423
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Wang, Wan& Qin, Suzi& Li, Linsen& Chen, Xiaohua& Wang, Qunjie& Wei, Junfu. An Optimized High Throughput Clean-Up Method Using Mixed-Mode SPE Plate for the Analysis of Free Arachidonic Acid in Plasma by LC-MSMS. International Journal of Analytical Chemistry. 2015. Vol. 2015, no. 2015, pp.1-6.
https://search.emarefa.net/detail/BIM-1064423
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1064423
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)