An Optimized High Throughput Clean-Up Method Using Mixed-Mode SPE Plate for the Analysis of Free Arachidonic Acid in Plasma by LC-MSMS

المؤلفون المشاركون

Wang, Wan
Qin, Suzi
Li, Linsen
Chen, Xiaohua
Wang, Qunjie
Wei, Junfu

المصدر

International Journal of Analytical Chemistry

العدد

المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-6، 6ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2015-03-19

دولة النشر

مصر

عدد الصفحات

6

التخصصات الرئيسية

الكيمياء
علوم

الملخص EN

A high throughput sample preparation method was developed utilizing mixed-mode solid phase extraction (SPE) in 96-well plate format for the determination of free arachidonic acid in plasma by LC-MS/MS.

Plasma was mixed with 3% aqueous ammonia and loaded into each well of 96-well plate.

After washing with water and methanol sequentially, 3% of formic acid in acetonitrile was used to elute arachidonic acid.

The collected fraction was injected onto a reversed phase column at 30°C with mobile phase of acetonitrile/water (70 : 30, v/v) and detected by LC-MS/MS coupled with electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode.

The calibration curve ranged from 10 to 2500 ng/mL with sufficient linearity (r 2 = 0.9999).

The recoveries were in the range of 99.38% to 103.21% with RSD less than 6%.

The limit of detection is 3 ng/mL.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Wang, Wan& Qin, Suzi& Li, Linsen& Chen, Xiaohua& Wang, Qunjie& Wei, Junfu. 2015. An Optimized High Throughput Clean-Up Method Using Mixed-Mode SPE Plate for the Analysis of Free Arachidonic Acid in Plasma by LC-MSMS. International Journal of Analytical Chemistry،Vol. 2015, no. 2015, pp.1-6.
https://search.emarefa.net/detail/BIM-1064423

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Wang, Wan…[et al.]. An Optimized High Throughput Clean-Up Method Using Mixed-Mode SPE Plate for the Analysis of Free Arachidonic Acid in Plasma by LC-MSMS. International Journal of Analytical Chemistry No. 2015 (2015), pp.1-6.
https://search.emarefa.net/detail/BIM-1064423

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Wang, Wan& Qin, Suzi& Li, Linsen& Chen, Xiaohua& Wang, Qunjie& Wei, Junfu. An Optimized High Throughput Clean-Up Method Using Mixed-Mode SPE Plate for the Analysis of Free Arachidonic Acid in Plasma by LC-MSMS. International Journal of Analytical Chemistry. 2015. Vol. 2015, no. 2015, pp.1-6.
https://search.emarefa.net/detail/BIM-1064423

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1064423