A Comparison of Casual In-Clinic Blood Pressure Measurements to Standardized Guideline-Concordant Measurements in Severely Obese Individuals

المؤلفون المشاركون

Vahidy, Sana
Padwal, Raj S.
Majumdar, Sumit R.

المصدر

International Journal of Hypertension

العدد

المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-5، 5ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2015-07-29

دولة النشر

مصر

عدد الصفحات

5

التخصصات الرئيسية

الأمراض
الطب البشري

الملخص EN

Background/Objectives.

The objective of this study was to compare casual BP taken in a bariatric clinic to standardized guideline-concordant BP.

Subjects/Methods.

A cross sectional analysis was performed using baseline data from a weight management trial.

Patients were recruited from a Canadian bariatric care program.

Standardized BP was performed using a Watch BP oscillometric device.

Casual in-clinic BP single readings, taken using a Welch Allyn oscillometric device, were chart-abstracted.

Paired t -tests, Bland-Altman plots, and Pearson’s correlations were used for analysis.

Results.

Data from 134 patients were analyzed.

Mean age was 41.5 ± 8.9 y, mean BMI was 46.8 ± 6.5 kg/m2, and 40 (30%) had prior hypertension.

Mean casual in-clinic BP was 128.8 ± 14.1/81.6 ± 9.9 mmHg and mean standardized BP was 133.2 ± 15.0/82.0 ± 10.3 mmHg (difference of −4.3 ± 12.0 for systolic ( p < 0.0001 ) and −0.4 ± 10.0 mmHg for diastolic BP ( p = 0.6 )).

Pearson’s coefficients were 0.66 ( p < 0.0001 ) for SBP and 0.50 ( p < 0.0001 ) for DBP.

28.4% of casual versus 26.9% of standardized measurements were ≥140/90 mmHg ( p < 0.0001 ).

Conclusion.

In this bariatric clinic, casual BP was unexpectedly lower than standardized BP.

This could potentially lead to the underdiagnosis of hypertension.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Vahidy, Sana& Majumdar, Sumit R.& Padwal, Raj S.. 2015. A Comparison of Casual In-Clinic Blood Pressure Measurements to Standardized Guideline-Concordant Measurements in Severely Obese Individuals. International Journal of Hypertension،Vol. 2015, no. 2015, pp.1-5.
https://search.emarefa.net/detail/BIM-1066131

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Vahidy, Sana…[et al.]. A Comparison of Casual In-Clinic Blood Pressure Measurements to Standardized Guideline-Concordant Measurements in Severely Obese Individuals. International Journal of Hypertension No. 2015 (2015), pp.1-5.
https://search.emarefa.net/detail/BIM-1066131

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Vahidy, Sana& Majumdar, Sumit R.& Padwal, Raj S.. A Comparison of Casual In-Clinic Blood Pressure Measurements to Standardized Guideline-Concordant Measurements in Severely Obese Individuals. International Journal of Hypertension. 2015. Vol. 2015, no. 2015, pp.1-5.
https://search.emarefa.net/detail/BIM-1066131

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1066131