الملخص EN

Purpose.

To thoroughly analyze corneal deformation responses curves obtained by Ocular Response Analyzer (ORA) testing in order to improve subclinical keratoconus detection.

Methods.

Observational case series of 87 control and 73 subclinical keratoconus eyes.

Examination included corneal topography, tomography, and biomechanical testing with ORA.

Factor analysis, logistic regression, and receiver operating characteristic curves were used to extract combinations of 45 corneal waveform descriptors.

Main outcome measures were corneal-thickness-corrected corneal resistance factor (ccCRF), combinations of corneal descriptors, and their diagnostic performance.

Results.

Thirty-seven descriptors differed significantly in means between groups, and among them ccCRF afforded the highest individual diagnostic performance.

Factor analysis identified first- and second-peak related descriptors as the most variable one.

However, conventional biomechanical descriptors corneal resistance factor and hysteresis differed the most between control and keratoconic eyes.

A combination of three factors including several corneal descriptors did not show better diagnostic performance than a combination of conventional indices.

Conclusion.

Multivariate analysis of ORA signals did not surpass simpler models in subclinical keratoconus detection, and there is considerable overlap between normal and ectatic eyes irrespective of the analysis model.

Conventional biomechanical indices seem to already provide the best performance when appropriately considered.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Galletti, Jonatán D.& Ruiseñor Vázquez, Pablo R.& Fuentes Bonthoux, Fernando& Pförtner, Tomás& Galletti, Jeremías G.. 2015. Multivariate Analysis of the Ocular Response Analyzer’s Corneal Deformation Response Curve for Early Keratoconus Detection. Journal of Ophthalmology،Vol. 2015, no. 2015, pp.1-8.
https://search.emarefa.net/detail/BIM-1069755

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Galletti, Jonatán D.…[et al.]. Multivariate Analysis of the Ocular Response Analyzer’s Corneal Deformation Response Curve for Early Keratoconus Detection. Journal of Ophthalmology No. 2015 (2015), pp.1-8.
https://search.emarefa.net/detail/BIM-1069755

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Galletti, Jonatán D.& Ruiseñor Vázquez, Pablo R.& Fuentes Bonthoux, Fernando& Pförtner, Tomás& Galletti, Jeremías G.. Multivariate Analysis of the Ocular Response Analyzer’s Corneal Deformation Response Curve for Early Keratoconus Detection. Journal of Ophthalmology. 2015. Vol. 2015, no. 2015, pp.1-8.
https://search.emarefa.net/detail/BIM-1069755

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1069755