Fiber-Optic Temperature and Pressure Sensors Applied to Radiofrequency Thermal Ablation in Liver Phantom: Methodology and Experimental Measurements

المؤلفون المشاركون

Macchi, Edoardo Gino
Cigada, Alfredo
Tosi, Daniele

المصدر

Journal of Sensors

العدد

المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-22، 22ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2015-01-20

دولة النشر

مصر

عدد الصفحات

22

التخصصات الرئيسية

هندسة مدنية

الملخص EN

Radiofrequency thermal ablation (RFA) is a procedure aimed at interventional cancer care and is applied to the treatment of small- and midsize tumors in lung, kidney, liver, and other tissues.

RFA generates a selective high-temperature field in the tissue; temperature values and their persistency are directly related to the mortality rate of tumor cells.

Temperature measurement in up to 3–5 points, using electrical thermocouples, belongs to the present clinical practice of RFA and is the foundation of a physical model of the ablation process.

Fiber-optic sensors allow extending the detection of biophysical parameters to a vast plurality of sensing points, using miniature and noninvasive technologies that do not alter the RFA pattern.

This work addresses the methodology for optical measurement of temperature distribution and pressure using four different fiber-optic technologies: fiber Bragg gratings (FBGs), linearly chirped FBGs (LCFBGs), Rayleigh scattering-based distributed temperature system (DTS), and extrinsic Fabry-Perot interferometry (EFPI).

For each instrument, methodology for ex vivo sensing, as well as experimental results, is reported, leading to the application of fiber-optic technologies in vivo.

The possibility of using a fiber-optic sensor network, in conjunction with a suitable ablation device, can enable smart ablation procedure whereas ablation parameters are dynamically changed.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Tosi, Daniele& Macchi, Edoardo Gino& Cigada, Alfredo. 2015. Fiber-Optic Temperature and Pressure Sensors Applied to Radiofrequency Thermal Ablation in Liver Phantom: Methodology and Experimental Measurements. Journal of Sensors،Vol. 2015, no. 2015, pp.1-22.
https://search.emarefa.net/detail/BIM-1070220

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Tosi, Daniele…[et al.]. Fiber-Optic Temperature and Pressure Sensors Applied to Radiofrequency Thermal Ablation in Liver Phantom: Methodology and Experimental Measurements. Journal of Sensors No. 2015 (2015), pp.1-22.
https://search.emarefa.net/detail/BIM-1070220

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Tosi, Daniele& Macchi, Edoardo Gino& Cigada, Alfredo. Fiber-Optic Temperature and Pressure Sensors Applied to Radiofrequency Thermal Ablation in Liver Phantom: Methodology and Experimental Measurements. Journal of Sensors. 2015. Vol. 2015, no. 2015, pp.1-22.
https://search.emarefa.net/detail/BIM-1070220

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1070220