A Statistic-Based Calibration Method for TIADC System

المؤلفون المشاركون

Ye, Peng
Yang, Kuojun
Zhang, Peng
Zheng, Yuanjin
Tian, Shulin

المصدر

Mathematical Problems in Engineering

العدد

المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-9، 9ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2015-02-22

دولة النشر

مصر

عدد الصفحات

9

التخصصات الرئيسية

هندسة مدنية

الملخص EN

Time-interleaved technique is widely used to increase the sampling rate of analog-to-digital converter (ADC).

However, the channel mismatches degrade the performance of time-interleaved ADC (TIADC).

Therefore, a statistic-based calibration method for TIADC is proposed in this paper.

The average value of sampling points is utilized to calculate offset error, and the summation of sampling points is used to calculate gain error.

After offset and gain error are obtained, they are calibrated by offset and gain adjustment elements in ADC.

Timing skew is calibrated by an iterative method.

The product of sampling points of two adjacent subchannels is used as a metric for calibration.

The proposed method is employed to calibrate mismatches in a four-channel 5 GS/s TIADC system.

Simulation results show that the proposed method can estimate mismatches accurately in a wide frequency range.

It is also proved that an accurate estimation can be obtained even if the signal noise ratio (SNR) of input signal is 20 dB.

Furthermore, the results obtained from a real four-channel 5 GS/s TIADC system demonstrate the effectiveness of the proposed method.

We can see that the spectra spurs due to mismatches have been effectively eliminated after calibration.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Yang, Kuojun& Tian, Shulin& Ye, Peng& Zhang, Peng& Zheng, Yuanjin. 2015. A Statistic-Based Calibration Method for TIADC System. Mathematical Problems in Engineering،Vol. 2015, no. 2015, pp.1-9.
https://search.emarefa.net/detail/BIM-1074475

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Yang, Kuojun…[et al.]. A Statistic-Based Calibration Method for TIADC System. Mathematical Problems in Engineering No. 2015 (2015), pp.1-9.
https://search.emarefa.net/detail/BIM-1074475

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Yang, Kuojun& Tian, Shulin& Ye, Peng& Zhang, Peng& Zheng, Yuanjin. A Statistic-Based Calibration Method for TIADC System. Mathematical Problems in Engineering. 2015. Vol. 2015, no. 2015, pp.1-9.
https://search.emarefa.net/detail/BIM-1074475

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1074475