Thermal-Hydraulic Assessment of W7-X Plasma Vessel Venting System in Case of 40 mm In-Vessel LOCA

المؤلفون المشاركون

Kaliatka, Tadas
Urbonavičius, E.

المصدر

Science and Technology of Nuclear Installations

العدد

المجلد 2015، العدد 2015 (31 ديسمبر/كانون الأول 2015)، ص ص. 1-9، 9ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2015-11-10

دولة النشر

مصر

عدد الصفحات

9

الملخص EN

This paper presents assessment of the capacity of W7-X venting system in response to in-vessel LOCA, rupture of 40 mm diameter pipe during operation mode “baking.” The integral analysis of the coolant release from the cooling system, pressurisation of PV, and response of the venting system is performed using RELAP5 code.

The same coolant release rate was introduced to the COCOSYS code, which is a lumped-parameter code developed for analysis of processes in containment of the light water reactors and the detailed analysis of the plasma vessel and the venting system is performed.

Different options of coolant release modeling available in COCOSYS are compared to define the base case model, which is further used for assessment of the other parameters, that is, the failure of one burst disk, the temperature in the environment, and the pressure losses in the piping of venting system.

The performed analysis identified the best option for coolant release modeling and showed that the capacity of the W7-X venting system is enough to prevent overpressure of the plasma vessel in the case of in-vessel LOCA.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Urbonavičius, E.& Kaliatka, Tadas. 2015. Thermal-Hydraulic Assessment of W7-X Plasma Vessel Venting System in Case of 40 mm In-Vessel LOCA. Science and Technology of Nuclear Installations،Vol. 2015, no. 2015, pp.1-9.
https://search.emarefa.net/detail/BIM-1077826

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Urbonavičius, E.& Kaliatka, Tadas. Thermal-Hydraulic Assessment of W7-X Plasma Vessel Venting System in Case of 40 mm In-Vessel LOCA. Science and Technology of Nuclear Installations No. 2015 (2015), pp.1-9.
https://search.emarefa.net/detail/BIM-1077826

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Urbonavičius, E.& Kaliatka, Tadas. Thermal-Hydraulic Assessment of W7-X Plasma Vessel Venting System in Case of 40 mm In-Vessel LOCA. Science and Technology of Nuclear Installations. 2015. Vol. 2015, no. 2015, pp.1-9.
https://search.emarefa.net/detail/BIM-1077826

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1077826