Influence of electrode material and EDM parameters on electrode wear of AISI H13 steel
المؤلفون المشاركون
Abd Allah, Mustafa Adil
Ubayd, Narin Hafiz
Radi, Asil Muhammad
Ahmad, Hibah Adil
المصدر
Wasit Journal of Engineering Sciences
العدد
المجلد 7، العدد 2 (31 أغسطس/آب 2019)، ص ص. 13-18، 6ص.
الناشر
تاريخ النشر
2019-08-31
دولة النشر
العراق
عدد الصفحات
6
التخصصات الرئيسية
الموضوعات
الملخص EN
Electrical discharge machining (EDM) is a non-traditional process that uses the electrical spark discharge to machine electrically conducting materials for geometrically complex shapes or hard materials.
In the current work, cupper and brass were used as the electrode material, and AISI H13 steel as the workpiece.
Different input parameters were investigated namely: 20, 30, 40 A current, 50, 100, 150 μs pulse on time, and 1, 3, 6 mm gap.
The workpiece thickness was fixed to 4 mm and the pulse off time was 25 μs.
All EDM experiments were carried out in diesel oil and the voltage was 140 V.
The results showed that the electrode wear decreased with increasing the pulse on time and gap and increased with increasing current for copper and brass electrode.
The optimal conditions for minimum tool wear were: pulse on time 150 μs, current 20 A, and gap 6 mm for copper and brass electrodes.
Electrode wear is minimum for copper at all parameter values compared to brass is a non-traditional process that uses the electrical spark discharge to machine electrically conducting materials for geometrically complex shapes or hard materials.
In the current work, cupper and brass were used as the electrode material, and AISI H13 steel as the workpiece.
Different input parameters were investigated namely: 20, 30, 40 A current, 50, 100, 150 μs pulse on time, and 1, 3, 6 mm gap.
The workpiece thickness was fixed to 4 mm and the pulse off time was 25 μs.
All EDM experiments were carried out in diesel oil and the voltage was 140 V.
The results showed that the electrode wear decreased with increasing the pulse on time and gap and increased with increasing current for copper and brass electrode.
The optimal conditions for minimum tool wear were: pulse on time 150 μs, current 20 A, and gap 6 mm for copper and brass electrodes.
Electrode wear is minimum for copper at all parameter values compared to brass electrode.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Abd Allah, Mustafa Adil& Ubayd, Narin Hafiz& Radi, Asil Muhammad& Ahmad, Hibah Adil. 2019. Influence of electrode material and EDM parameters on electrode wear of AISI H13 steel. Wasit Journal of Engineering Sciences،Vol. 7, no. 2, pp.13-18.
https://search.emarefa.net/detail/BIM-1094134
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Abd Allah, Mustafa Adil…[et al.]. Influence of electrode material and EDM parameters on electrode wear of AISI H13 steel. Wasit Journal of Engineering Sciences Vol. 7, no. 2 (2019), pp.13-18.
https://search.emarefa.net/detail/BIM-1094134
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Abd Allah, Mustafa Adil& Ubayd, Narin Hafiz& Radi, Asil Muhammad& Ahmad, Hibah Adil. Influence of electrode material and EDM parameters on electrode wear of AISI H13 steel. Wasit Journal of Engineering Sciences. 2019. Vol. 7, no. 2, pp.13-18.
https://search.emarefa.net/detail/BIM-1094134
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references : p. 18
رقم السجل
BIM-1094134
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر