A DIC Based Technique to Measure the Contraction of a Skeletal Muscle Engineered Tissue

المؤلفون المشاركون

Musarò, Antonio
Rizzuto, Emanuele
Carosio, Silvia
Faraldi, Martina
Pisu, Simona
Del Prete, Zaccaria

المصدر

Applied Bionics and Biomechanics

العدد

المجلد 2016، العدد 2016 (31 ديسمبر/كانون الأول 2016)، ص ص. 1-7، 7ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2016-03-09

دولة النشر

مصر

عدد الصفحات

7

التخصصات الرئيسية

الأحياء

الملخص EN

Tissue engineering is a multidisciplinary science based on the application of engineering approaches to biologic tissue formation.

Engineered tissue internal organization represents a key aspect to increase biofunctionality before transplant and, as regarding skeletal muscles, the potential of generating contractile forces is dependent on the internal fiber organization and is reflected by some macroscopic parameters, such as the spontaneous contraction.

Here we propose the application of digital image correlation (DIC) as an independent tool for an accurate and noninvasive measurement of engineered muscle tissue spontaneous contraction.

To validate the proposed technique we referred to the X-MET, a promising 3-dimensional model of skeletal muscle.

The images acquired through a high speed camera were correlated with a custom-made algorithm and the longitudinal strain predictions were employed for measuring the spontaneous contraction.

The spontaneous contraction reference values were obtained by studying the force response.

The relative error between the spontaneous contraction frequencies computed in both ways was always lower than 0.15%.

In conclusion, the use of a DIC based system allows for an accurate and noninvasive measurement of biological tissues’ spontaneous contraction, in addition to the measurement of tissue strain field on any desired region of interest during electrical stimulation.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Rizzuto, Emanuele& Carosio, Silvia& Faraldi, Martina& Pisu, Simona& Musarò, Antonio& Del Prete, Zaccaria. 2016. A DIC Based Technique to Measure the Contraction of a Skeletal Muscle Engineered Tissue. Applied Bionics and Biomechanics،Vol. 2016, no. 2016, pp.1-7.
https://search.emarefa.net/detail/BIM-1094831

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Rizzuto, Emanuele…[et al.]. A DIC Based Technique to Measure the Contraction of a Skeletal Muscle Engineered Tissue. Applied Bionics and Biomechanics No. 2016 (2016), pp.1-7.
https://search.emarefa.net/detail/BIM-1094831

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Rizzuto, Emanuele& Carosio, Silvia& Faraldi, Martina& Pisu, Simona& Musarò, Antonio& Del Prete, Zaccaria. A DIC Based Technique to Measure the Contraction of a Skeletal Muscle Engineered Tissue. Applied Bionics and Biomechanics. 2016. Vol. 2016, no. 2016, pp.1-7.
https://search.emarefa.net/detail/BIM-1094831

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1094831