Fault Diagnosis of a High-Speed Cam-Driven Pin Assembly System
المؤلفون المشاركون
Cheng, Chi-Cheng
Tseng, Yih-Tun
Wu, Cheng-Da
Wang, Der-Lin
المصدر
Advances in Materials Science and Engineering
العدد
المجلد 2016، العدد 2016 (31 ديسمبر/كانون الأول 2016)، ص ص. 1-14، 14ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2016-03-03
دولة النشر
مصر
عدد الصفحات
14
الملخص EN
A cam-driven mechanical system applied for pin assembly of connectors of electrical devices is studied in this paper.
Three cooperative cams are involved in the tasks of approaching, cutting, insertion, and restoring.
In order to meet the demanded productivity growth, the operation speed tends to be elevated.
However, high running speeds usually cause deficiencies of pin dropping and inaccurate positioning.
Diagnosis is therefore conducted to explore their physical reasons so that modification of future mechanical design can be made.
Frequency responses of experimental measurements show greater natural frequency and system stiffness caused by nonlinear dynamics for higher operation speed.
It also appears that the clamping force is reduced and drift of the locked pin’s location is induced for higher running speed.
In addition, separation of the fixture system induced by contact oscillation generates clearance larger than the thickness of the pin.
Based on the mathematical models obtained from the technique of system identification, deeper insight of the mechanical system and future system improvement can be highly expected.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Cheng, Chi-Cheng& Tseng, Yih-Tun& Wu, Cheng-Da& Wang, Der-Lin. 2016. Fault Diagnosis of a High-Speed Cam-Driven Pin Assembly System. Advances in Materials Science and Engineering،Vol. 2016, no. 2016, pp.1-14.
https://search.emarefa.net/detail/BIM-1096240
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Cheng, Chi-Cheng…[et al.]. Fault Diagnosis of a High-Speed Cam-Driven Pin Assembly System. Advances in Materials Science and Engineering No. 2016 (2016), pp.1-14.
https://search.emarefa.net/detail/BIM-1096240
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Cheng, Chi-Cheng& Tseng, Yih-Tun& Wu, Cheng-Da& Wang, Der-Lin. Fault Diagnosis of a High-Speed Cam-Driven Pin Assembly System. Advances in Materials Science and Engineering. 2016. Vol. 2016, no. 2016, pp.1-14.
https://search.emarefa.net/detail/BIM-1096240
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1096240
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر