Effect of Chlorides on Conductivity and Dielectric Constant in Hardened Cement Mortar: NDT for Durability Evaluation
المؤلفون المشاركون
Lee, Sanghyo
Kang, Joo-Won
Ahn, Yong Han
Kim, Sunkook
المصدر
Advances in Materials Science and Engineering
العدد
المجلد 2016، العدد 2016 (31 ديسمبر/كانون الأول 2016)، ص ص. 1-9، 9ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2016-05-24
دولة النشر
مصر
عدد الصفحات
9
الملخص EN
Dielectric constant and conductivity, the so-called EM properties (electromagnetic), are widely adopted for NDT (Nondestructive Technique) in order to detect damage or evaluate performance of concrete without damage to existing RC (reinforced concrete).
Among deteriorating agents, chloride ion is considered as one of the most critical threats due to rapid penetration and direct effect on steel corrosion.
In the work, cement mortar samples with 3 w/c (water-to-cement) ratios and 4 levels of chloride addition are considered.
Conductivity and dielectric constant are measured in the normal frequency range.
They increase with strength of mortar and more chloride ions due to denser pore formation.
Furthermore, the behaviors of measured EM property are investigated with carbonation velocity and strength, which shows an attempt of application to durability evaluation through EM measurement.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Kim, Sunkook& Kang, Joo-Won& Lee, Sanghyo& Ahn, Yong Han. 2016. Effect of Chlorides on Conductivity and Dielectric Constant in Hardened Cement Mortar: NDT for Durability Evaluation. Advances in Materials Science and Engineering،Vol. 2016, no. 2016, pp.1-9.
https://search.emarefa.net/detail/BIM-1096253
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Kim, Sunkook…[et al.]. Effect of Chlorides on Conductivity and Dielectric Constant in Hardened Cement Mortar: NDT for Durability Evaluation. Advances in Materials Science and Engineering No. 2016 (2016), pp.1-9.
https://search.emarefa.net/detail/BIM-1096253
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Kim, Sunkook& Kang, Joo-Won& Lee, Sanghyo& Ahn, Yong Han. Effect of Chlorides on Conductivity and Dielectric Constant in Hardened Cement Mortar: NDT for Durability Evaluation. Advances in Materials Science and Engineering. 2016. Vol. 2016, no. 2016, pp.1-9.
https://search.emarefa.net/detail/BIM-1096253
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1096253
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر