A new multifunction power amplifier (MFPA) is designed and fabricated for the application of point-to-point K-Band backhaul TR module.

A DC temperature life test was performed to model the up-limit temperature effect of the designed MFPA under space application.

After 240 hours of 100°C life test, the test results illustrate that the designed MFPA has only slight power degradation at the saturation region without change of the linear gain.

The general performance of the designed MFPA satisfies the requirement of the application scenario.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Xu, Xiuqin& Xu, Hui& Shang, Yongheng& Wang, Zhiyu& Wang, Yang& Wang, Liping…[et al.]. 2016. The Design and Life Test of a Multifunction Power Amplifier for Space Application. Active and Passive Electronic Components،Vol. 2016, no. 2016, pp.1-6.
https://search.emarefa.net/detail/BIM-1096564

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Xu, Xiuqin…[et al.]. The Design and Life Test of a Multifunction Power Amplifier for Space Application. Active and Passive Electronic Components No. 2016 (2016), pp.1-6.
https://search.emarefa.net/detail/BIM-1096564

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Xu, Xiuqin& Xu, Hui& Shang, Yongheng& Wang, Zhiyu& Wang, Yang& Wang, Liping…[et al.]. The Design and Life Test of a Multifunction Power Amplifier for Space Application. Active and Passive Electronic Components. 2016. Vol. 2016, no. 2016, pp.1-6.
https://search.emarefa.net/detail/BIM-1096564

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1096564