Feasibility and Safety of Absorbable Knotless Wound Closure Device in Laparoscopic Myomectomy

المؤلفون المشاركون

Chan, Chying-Chyuan
Lee, Ching-Yu

المصدر

BioMed Research International

العدد

المجلد 2016، العدد 2016 (31 ديسمبر/كانون الأول 2016)، ص ص. 1-5، 5ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2016-06-27

دولة النشر

مصر

عدد الصفحات

5

التخصصات الرئيسية

الطب البشري

الملخص EN

Purpose.

Myomectomy has been performed through laparoscopy.

Suturing is known as rate-limiting step in laparoscopic myomectomy.

The present study was aimed at comparing the clinical outcomes of absorbable knotless wound closure device with the results of conventional suturing.

Methods.

This prospective study included 62 women who underwent laparoscopic myomectomy at Taipei City Hospital, Zhongxiao Branch, from January 2010 through to August 2012.

The patients were randomized into two groups according to suturing materials, the knotless group and the 2-0 Vicryl suture group.

Patient demographics, overall operative time, and intraoperative blood loss were compared between two groups.

Results.

Demographic characteristics and laboratory variables before surgery were comparable.

Operative time was significantly shorter in knotless group compared with that in 2-0 Vicryl suture group ( 112 ± 47 versus 147 ± 63 minutes; p < 0.05 ).

The results revealed a significant difference in intraoperative blood loss between two groups (knotless versus 2-0 Vicryl: 112.8 ± 54.2 versus 143.6 ± 64.9 ).

Use of absorbable knotless wound closure device was associated with greater hemostasis compared with that of 2-0 Vicryl.

During a 2-year follow-up period, 12 patients (46.2%) from the group with absorbable knotless wound closure device and 14 patients (38.9%) from 2-0 Vicryl suture group became pregnant.

Conclusion.

Closure of myometrium using absorbable knotless wound closure device after laparoscopic myomectomy resulted in a shorter operative time and less blood loss.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Chan, Chying-Chyuan& Lee, Ching-Yu. 2016. Feasibility and Safety of Absorbable Knotless Wound Closure Device in Laparoscopic Myomectomy. BioMed Research International،Vol. 2016, no. 2016, pp.1-5.
https://search.emarefa.net/detail/BIM-1097172

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Chan, Chying-Chyuan& Lee, Ching-Yu. Feasibility and Safety of Absorbable Knotless Wound Closure Device in Laparoscopic Myomectomy. BioMed Research International No. 2016 (2016), pp.1-5.
https://search.emarefa.net/detail/BIM-1097172

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Chan, Chying-Chyuan& Lee, Ching-Yu. Feasibility and Safety of Absorbable Knotless Wound Closure Device in Laparoscopic Myomectomy. BioMed Research International. 2016. Vol. 2016, no. 2016, pp.1-5.
https://search.emarefa.net/detail/BIM-1097172

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1097172