The 3D Tele Motion Tracking for the Orthodontic Facial Analysis

المؤلفون المشاركون

Mummolo, Stefano
Nota, Alessandro
Marchetti, Enrico
Padricelli, Giuseppe
Marzo, Giuseppe

المصدر

BioMed Research International

العدد

المجلد 2016، العدد 2016 (31 ديسمبر/كانون الأول 2016)، ص ص. 1-6، 6ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2016-12-01

دولة النشر

مصر

عدد الصفحات

6

التخصصات الرئيسية

الطب البشري

الملخص EN

Aim.

This study aimed to evaluate the reliability of 3D-TMT, previously used only for dynamic testing, in a static cephalometric evaluation.

Material and Method.

A group of 40 patients (20 males and 20 females; mean age 14.2±1.2 years; 12–18 years old) was included in the study.

The measurements obtained by the 3D-TMT cephalometric analysis with a conventional frontal cephalometric analysis were compared for each subject.

Nine passive markers reflectors were positioned on the face skin for the detection of the profile of the patient.

Through the acquisition of these points, corresponding plans for three-dimensional posterior-anterior cephalometric analysis were found.

Results.

The cephalometric results carried out with 3D-TMT and with traditional posterior-anterior cephalometric analysis showed the 3D-TMT system values are slightly higher than the values measured on radiographs but statistically significant; nevertheless their correlation is very high.

Conclusion.

The recorded values obtained using the 3D-TMT analysis were correlated to cephalometric analysis, with small but statistically significant differences.

The Dahlberg errors resulted to be always lower than the mean difference between the 2D and 3D measurements.

A clinician should use, during the clinical monitoring of a patient, always the same method, to avoid comparing different millimeter magnitudes.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Mummolo, Stefano& Nota, Alessandro& Marchetti, Enrico& Padricelli, Giuseppe& Marzo, Giuseppe. 2016. The 3D Tele Motion Tracking for the Orthodontic Facial Analysis. BioMed Research International،Vol. 2016, no. 2016, pp.1-6.
https://search.emarefa.net/detail/BIM-1097946

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Mummolo, Stefano…[et al.]. The 3D Tele Motion Tracking for the Orthodontic Facial Analysis. BioMed Research International No. 2016 (2016), pp.1-6.
https://search.emarefa.net/detail/BIM-1097946

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Mummolo, Stefano& Nota, Alessandro& Marchetti, Enrico& Padricelli, Giuseppe& Marzo, Giuseppe. The 3D Tele Motion Tracking for the Orthodontic Facial Analysis. BioMed Research International. 2016. Vol. 2016, no. 2016, pp.1-6.
https://search.emarefa.net/detail/BIM-1097946

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1097946