الملخص EN

Stress shielding is a well-known failure factor in hip implants.

This work proposes a design concept for hip implants, using a combination of metallic stem with a polymer coating (polyether ether ketone (PEEK)).

The proposed design concept is simulated using titanium alloy stems and PEEK coatings with thicknesses varying from 100 to 400 μm.

The Finite Element analysis of the cancellous bone surrounding the implant shows promising results.

The effective von Mises stress increases between 81 and 92% for the complete volume of cancellous bone.

When focusing on the proximal zone of the implant, the increased stress transmission to the cancellous bone reaches between 47 and 60%.

This increment in load transferred to the bone can influence mineral bone loss due to stress shielding, minimizing such effect, and thus prolonging implant lifespan.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Anguiano-Sanchez, Jesica& Martínez-Romero, Oscar& Siller, Héctor R.& Díaz-Elizondo, José A.& Flores-Villalba, Eduardo& Rodríguez, Ciro A.. 2016. Influence of PEEK Coating on Hip Implant Stress Shielding: A Finite Element Analysis. Computational and Mathematical Methods in Medicine،Vol. 2016, no. 2016, pp.1-10.
https://search.emarefa.net/detail/BIM-1100159

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Anguiano-Sanchez, Jesica…[et al.]. Influence of PEEK Coating on Hip Implant Stress Shielding: A Finite Element Analysis. Computational and Mathematical Methods in Medicine No. 2016 (2016), pp.1-10.
https://search.emarefa.net/detail/BIM-1100159

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Anguiano-Sanchez, Jesica& Martínez-Romero, Oscar& Siller, Héctor R.& Díaz-Elizondo, José A.& Flores-Villalba, Eduardo& Rodríguez, Ciro A.. Influence of PEEK Coating on Hip Implant Stress Shielding: A Finite Element Analysis. Computational and Mathematical Methods in Medicine. 2016. Vol. 2016, no. 2016, pp.1-10.
https://search.emarefa.net/detail/BIM-1100159

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1100159