Combined Scleral Flap with Donor Scleral Patch Graft for Anterior Tube Placement in Glaucoma Drainage Device Surgery
المؤلفون المشاركون
Yu, Jea H.
Nguyen, Chuck
Gallemore, Esmeralda
Gallemore, Ron P.
المصدر
Case Reports in Ophthalmological Medicine
العدد
المجلد 2016، العدد 2016 (31 ديسمبر/كانون الأول 2016)، ص ص. 1-4، 4ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2016-09-25
دولة النشر
مصر
عدد الصفحات
4
التخصصات الرئيسية
الملخص EN
Purpose.
To report a new technique for anterior placement of tubes for glaucoma drainage devices to reduce the risk of tube erosions.
Methods.
Retrospective review of select cases of Ahmed Valve surgery combined with the novel method of a limbal-based scleral flap covered by a scleral patch graft to cover the tube at the entrance through the limbus.
Intraoperative and postoperative illustrations are shown to highlight the method of tube placement.
Results.
In this retrospective case series, 3 patients are presented illustrating the technique.
Two had neovascular glaucoma and one had primary open-angle glaucoma (POAG).
On average, intraocular pressure was reduced from 39±14 mmHg to 15±2 mmHg and the number of glaucoma medications was reduced from 4±1 to 0.
Preoperative and most recent visual acuities were hand-motion (HM) and HM, 20/60 and 20/50, and 20/70 and 20/30, respectively.
Conclusion.
The combination of a limbal-based scleral flap with scleral patch graft to cover the tube with glaucoma drainage devices may be an effective means to reduce erosion and protect against endophthalmitis.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Yu, Jea H.& Nguyen, Chuck& Gallemore, Esmeralda& Gallemore, Ron P.. 2016. Combined Scleral Flap with Donor Scleral Patch Graft for Anterior Tube Placement in Glaucoma Drainage Device Surgery. Case Reports in Ophthalmological Medicine،Vol. 2016, no. 2016, pp.1-4.
https://search.emarefa.net/detail/BIM-1101784
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Yu, Jea H.…[et al.]. Combined Scleral Flap with Donor Scleral Patch Graft for Anterior Tube Placement in Glaucoma Drainage Device Surgery. Case Reports in Ophthalmological Medicine No. 2016 (2016), pp.1-4.
https://search.emarefa.net/detail/BIM-1101784
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Yu, Jea H.& Nguyen, Chuck& Gallemore, Esmeralda& Gallemore, Ron P.. Combined Scleral Flap with Donor Scleral Patch Graft for Anterior Tube Placement in Glaucoma Drainage Device Surgery. Case Reports in Ophthalmological Medicine. 2016. Vol. 2016, no. 2016, pp.1-4.
https://search.emarefa.net/detail/BIM-1101784
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1101784
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر