الملخص EN
Objective.
The aim of this study is to analyze the hearing and vestibular outcome of patients with otosclerosis who have been operated on by fiber optic flexible CO2 laser.
Study Design.
A preliminary and retrospective study was conducted in 30 patients with otosclerosis.
Results.
Comparative analysis of average air conduction thresholds ( 53.41 ± 11.81 dB versus 26.37 ± 11.04 dB) and air-bone gaps ( 34 ± 9.92 dB versus 12.03 ± 6.02 dB) before and after the surgery were statistically significant (<0.001).
Air-bone gap closed within 10 dB or less in 50% of the cases and within 20 dB or less in 90% of the cases.
Average bone conduction threshold after the surgery ( 16.68 ± 12.00 dB) was better than that before the surgery ( 20.13 ± 8.59 ).
However, no statistically significant difference was found ( p = 0.213 ).
One patient had tinnitus after surgery.
None of the patients had severe sickness or vomiting due to surgery.
Eleven patients (36.6%) had very mild nystagmus beating toward the counter-lateral side.
All patients were stable at 10 days after surgery.
Conclusion.
The results indicate that fiber optic flexible CO2 laser provides the surgeon with a very safe and precise surgical instrumentation even in cases with extensive and obliterative otosclerosis.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Yetiser, Sertac. 2016. Flexible Fiber Optic Carbon-Dioxide Laser Assisted Stapedotomy in Otosclerosis. International Journal of Otolaryngology،Vol. 2016, no. 2016, pp.1-5.
https://search.emarefa.net/detail/BIM-1106405
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Yetiser, Sertac. Flexible Fiber Optic Carbon-Dioxide Laser Assisted Stapedotomy in Otosclerosis. International Journal of Otolaryngology No. 2016 (2016), pp.1-5.
https://search.emarefa.net/detail/BIM-1106405
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Yetiser, Sertac. Flexible Fiber Optic Carbon-Dioxide Laser Assisted Stapedotomy in Otosclerosis. International Journal of Otolaryngology. 2016. Vol. 2016, no. 2016, pp.1-5.
https://search.emarefa.net/detail/BIM-1106405
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1106405
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر