Cerebrospinal Fluid Leak in Cochlear Implantation: Enlarged Cochlear versus Enlarged Vestibular Aqueduct (Common Cavity Excluded)‎

المؤلفون المشاركون

Bianchin, Giovanni
Polizzi, Valeria
Formigoni, Patrizia
Russo, Carmela
Tribi, Lorenzo

المصدر

International Journal of Otolaryngology

العدد

المجلد 2016، العدد 2016 (31 ديسمبر/كانون الأول 2016)، ص ص. 1-9، 9ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2016-10-26

دولة النشر

مصر

عدد الصفحات

9

التخصصات الرئيسية

الطب البشري

الملخص EN

Objective.

To share our experience of cerebrospinal fluid gusher in cochlear implantation in patients with enlarged cochlear or vestibular aqueduct.

Study Design.

Case series with comparison and a review of the literature.

Methods.

A retrospective study was performed.

Demographic and radiological results of patients with enlarged cochlear aqueduct or enlarged vestibular aqueduct in 278 consecutive cochlear implant recipients, including children and adults, were evaluated between January 2000 and December 2015.

Results.

Six patients with enlarged cochlear aqueduct and eight patients with enlarged vestibular aqueduct were identified.

Cerebrospinal fluid gusher occurs in five subjects with enlarged cochlear aqueduct and in only one case of enlarged vestibular aqueduct.

Conclusion.

Based on these findings, enlarged cochlear aqueduct may be the best risk predictor of cerebrospinal fluid gusher at cochleostomy during cochlear implant surgery despite enlarged vestibular aqueduct.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Bianchin, Giovanni& Polizzi, Valeria& Formigoni, Patrizia& Russo, Carmela& Tribi, Lorenzo. 2016. Cerebrospinal Fluid Leak in Cochlear Implantation: Enlarged Cochlear versus Enlarged Vestibular Aqueduct (Common Cavity Excluded). International Journal of Otolaryngology،Vol. 2016, no. 2016, pp.1-9.
https://search.emarefa.net/detail/BIM-1106416

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Bianchin, Giovanni…[et al.]. Cerebrospinal Fluid Leak in Cochlear Implantation: Enlarged Cochlear versus Enlarged Vestibular Aqueduct (Common Cavity Excluded). International Journal of Otolaryngology No. 2016 (2016), pp.1-9.
https://search.emarefa.net/detail/BIM-1106416

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Bianchin, Giovanni& Polizzi, Valeria& Formigoni, Patrizia& Russo, Carmela& Tribi, Lorenzo. Cerebrospinal Fluid Leak in Cochlear Implantation: Enlarged Cochlear versus Enlarged Vestibular Aqueduct (Common Cavity Excluded). International Journal of Otolaryngology. 2016. Vol. 2016, no. 2016, pp.1-9.
https://search.emarefa.net/detail/BIM-1106416

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1106416