Total Arsenic, Cadmium, and Lead Determination in Brazilian Rice Samples Using ICP-MS

المؤلفون المشاركون

Mataveli, Lidiane Raquel Verola
Buzzo, Márcia Liane
Arauz, Luciana Juncioni de
Carvalho, Maria de Fátima Henriques
Arakaki, Edna Emy Kumagai
Matsuzaki, Richard
Tiglea, Paulo

المصدر

Journal of Analytical Methods in Chemistry

العدد

المجلد 2016، العدد 2016 (31 ديسمبر/كانون الأول 2016)، ص ص. 1-9، 9ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2016-09-28

دولة النشر

مصر

عدد الصفحات

9

التخصصات الرئيسية

الكيمياء

الملخص EN

This study is aimed at investigating a suitable method for rice sample preparation as well as validating and applying the method for monitoring the concentration of total arsenic, cadmium, and lead in rice by using Inductively Coupled Plasma Mass Spectrometry (ICP-MS).

Various rice sample preparation procedures were evaluated.

The analytical method was validated by measuring several parameters including limit of detection (LOD), limit of quantification (LOQ), linearity, relative bias, and repeatability.

Regarding the sample preparation, recoveries of spiked samples were within the acceptable range from 89.3 to 98.2% for muffle furnace, 94.2 to 103.3% for heating block, 81.0 to 115.0% for hot plate, and 92.8 to 108.2% for microwave.

Validation parameters showed that the method fits for its purpose, being the total arsenic, cadmium, and lead within the Brazilian Legislation limits.

The method was applied for analyzing 37 rice samples (including polished, brown, and parboiled), consumed by the Brazilian population.

The total arsenic, cadmium, and lead contents were lower than the established legislative values, except for total arsenic in one brown rice sample.

This study indicated the need to establish monitoring programs for emphasizing the study on this type of cereal, aiming at promoting the Public Health.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Mataveli, Lidiane Raquel Verola& Buzzo, Márcia Liane& Arauz, Luciana Juncioni de& Carvalho, Maria de Fátima Henriques& Arakaki, Edna Emy Kumagai& Matsuzaki, Richard…[et al.]. 2016. Total Arsenic, Cadmium, and Lead Determination in Brazilian Rice Samples Using ICP-MS. Journal of Analytical Methods in Chemistry،Vol. 2016, no. 2016, pp.1-9.
https://search.emarefa.net/detail/BIM-1107310

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Mataveli, Lidiane Raquel Verola…[et al.]. Total Arsenic, Cadmium, and Lead Determination in Brazilian Rice Samples Using ICP-MS. Journal of Analytical Methods in Chemistry No. 2016 (2016), pp.1-9.
https://search.emarefa.net/detail/BIM-1107310

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Mataveli, Lidiane Raquel Verola& Buzzo, Márcia Liane& Arauz, Luciana Juncioni de& Carvalho, Maria de Fátima Henriques& Arakaki, Edna Emy Kumagai& Matsuzaki, Richard…[et al.]. Total Arsenic, Cadmium, and Lead Determination in Brazilian Rice Samples Using ICP-MS. Journal of Analytical Methods in Chemistry. 2016. Vol. 2016, no. 2016, pp.1-9.
https://search.emarefa.net/detail/BIM-1107310

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1107310