Relating Corroded Seven-Strand, Posttensioned Cable Cross-Sectional Properties to Load Capacity

المؤلفون المشاركون

Haskins, Richard
White, Barry
Ebeling, Robert
Evans, James

المصدر

Journal of Engineering

العدد

المجلد 2016، العدد 2016 (31 ديسمبر/كانون الأول 2016)، ص ص. 1-10، 10ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2016-10-27

دولة النشر

مصر

عدد الصفحات

10

التخصصات الرئيسية

هندسة مدنية

الملخص EN

Multistrand anchors have seen widespread use, providing strength and stability at hydraulic Corps facilities.

However, these steel tendons are subject to strength reduction as an effect of corrosion.

Methods for evaluating the corroded cable strength do not exist to accurately estimate the time until tendon cables would have to be replaced (at great expense).

The following five research tasks are used to address this deficiency: laboratory accelerated corrosion; pull-tests on pristine and laboratory corroded cables; optical scanning; data collection correlated with cross-sectional properties of cables; and development of a method to relate this data to the field.

The pull-tests provide measured capacities for seven-strand, posttensioned (PT) cables.

An optical scan of the corroded cables provides cross-sectional properties of individual wires within the pulled cables.

Trendlines are established for the related peak cable capacities and cross-sectional properties in an effort to determine their correlations.

Trendlines for minimum wire area and second-moment short axis diameter are found with low error, making them good predictors of loaded cable capacity.

This pull-test dataset has been related back to cable failure in the field, assuming a linear rate of corrosion loss for the cross-sectional properties and required PT capacity.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Haskins, Richard& White, Barry& Ebeling, Robert& Evans, James. 2016. Relating Corroded Seven-Strand, Posttensioned Cable Cross-Sectional Properties to Load Capacity. Journal of Engineering،Vol. 2016, no. 2016, pp.1-10.
https://search.emarefa.net/detail/BIM-1108373

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Haskins, Richard…[et al.]. Relating Corroded Seven-Strand, Posttensioned Cable Cross-Sectional Properties to Load Capacity. Journal of Engineering No. 2016 (2016), pp.1-10.
https://search.emarefa.net/detail/BIM-1108373

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Haskins, Richard& White, Barry& Ebeling, Robert& Evans, James. Relating Corroded Seven-Strand, Posttensioned Cable Cross-Sectional Properties to Load Capacity. Journal of Engineering. 2016. Vol. 2016, no. 2016, pp.1-10.
https://search.emarefa.net/detail/BIM-1108373

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1108373