Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software
المؤلفون المشاركون
Mei, Ying
Tang, Zhiping
Li, Zhouyue
Yang, Xiao
المصدر
العدد
المجلد 2016، العدد 2016 (31 ديسمبر/كانون الأول 2016)، ص ص. 1-7، 7ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2016-09-28
دولة النشر
مصر
عدد الصفحات
7
التخصصات الرئيسية
الملخص EN
Purpose.
To evaluate the repeatability and reproducibility of quantitative analysis of the morphological corneal changes after orthokeratology treatment using “Image-Pro Plus 6.0” software (IPP).
Methods.
Three sets of measurements were obtained: two sets by examiner 1 with 5 days apart and one set by examiner 2 on the same day.
Parameters of the eccentric distance, eccentric angle, area, and roundness of the corneal treatment zone were measured using IPP.
The intraclass correlation coefficient (ICC) and repetitive coefficient (COR) were used to calculate the repeatability and reproducibility of these three sets of measurements.
Results.
ICC analysis suggested “excellent” reliability of more than 0.885 for all variables, and COR values were less than 10% for all variables within the same examiner.
ICC analysis suggested “excellent” reliability for all variables of more than 0.90, and COR values were less than 10% for all variables between different examiners.
All extreme values of the eccentric distance and area of the treatment zone pointed to the same material number in three sets of measurements.
Conclusions.
IPP could be used to acquire the exact data of the characteristic morphological corneal changes after orthokeratology treatment with good repeatability and reproducibility.
This trial is registered with trial registration number: ChiCTR-IPR-14005505.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Mei, Ying& Tang, Zhiping& Li, Zhouyue& Yang, Xiao. 2016. Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software. Journal of Ophthalmology،Vol. 2016, no. 2016, pp.1-7.
https://search.emarefa.net/detail/BIM-1109868
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Mei, Ying…[et al.]. Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software. Journal of Ophthalmology No. 2016 (2016), pp.1-7.
https://search.emarefa.net/detail/BIM-1109868
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Mei, Ying& Tang, Zhiping& Li, Zhouyue& Yang, Xiao. Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software. Journal of Ophthalmology. 2016. Vol. 2016, no. 2016, pp.1-7.
https://search.emarefa.net/detail/BIM-1109868
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1109868
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)