Accuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes

المؤلفون المشاركون

Zhang, Yichi
Liang, Xiao Ying
Liu, Shu
Bhaskar, Srinivasan
Lam, Dennis S. C.
Lee, Jacky

المصدر

Journal of Ophthalmology

العدد

المجلد 2016، العدد 2016 (31 ديسمبر/كانون الأول 2016)، ص ص. 1-7، 7ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2016-03-29

دولة النشر

مصر

عدد الصفحات

7

التخصصات الرئيسية

الطب البشري

الملخص EN

Purpose.

To evaluate and compare the accuracy of different intraocular lens (IOL) power calculation formulas for eyes with an axial length (AL) greater than 26.00 mm.

Methods.

This study reviewed 407 eyes of 219 patients with AL longer than 26.0 mm.

The refractive prediction errors of IOL power calculation formulas (SRK/T, Haigis, Holladay, Hoffer Q, and Barrett Universal II) using User Group for Laser Interference Biometry (ULIB) constants were evaluated and compared.

Results.

One hundred seventy-one eyes were enrolled.

The Barrett Universal II formula had the lowest mean absolute error (MAE) and SRK/T and Haigis had similar MAE, and the statistical highest MAE were seen with the Holladay and Hoffer Q formulas.

The interquartile range of the Barrett Universal II formula was also the lowest among all the formulas.

The Barrett Universal II formulas yielded the highest percentage of eyes within ±1.0 D and ±0.5 D of the target refraction in this study (97.24% and 79.56%, resp.).

Conclusions.

Barrett Universal II formula produced the lowest predictive error and the least variable predictive error compared with the SRK/T, Haigis, Holladay, and Hoffer Q formulas.

For high myopic eyes, the Barrett Universal II formula may be a more suitable choice.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Zhang, Yichi& Liang, Xiao Ying& Liu, Shu& Lee, Jacky& Bhaskar, Srinivasan& Lam, Dennis S. C.. 2016. Accuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes. Journal of Ophthalmology،Vol. 2016, no. 2016, pp.1-7.
https://search.emarefa.net/detail/BIM-1109873

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Zhang, Yichi…[et al.]. Accuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes. Journal of Ophthalmology No. 2016 (2016), pp.1-7.
https://search.emarefa.net/detail/BIM-1109873

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Zhang, Yichi& Liang, Xiao Ying& Liu, Shu& Lee, Jacky& Bhaskar, Srinivasan& Lam, Dennis S. C.. Accuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes. Journal of Ophthalmology. 2016. Vol. 2016, no. 2016, pp.1-7.
https://search.emarefa.net/detail/BIM-1109873

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1109873