Passive Removal of Silicone Oil with Temporal Head Position through Two 23-Gauge Cannulas
المؤلفون المشاركون
Lin, Zhong
Ke, Zhi Sheng
Zheng, Qian
Zhao, Zhen Quan
Song, Zong Ming
المصدر
العدد
المجلد 2016، العدد 2016 (31 ديسمبر/كانون الأول 2016)، ص ص. 1-4، 4ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2016-06-22
دولة النشر
مصر
عدد الصفحات
4
التخصصات الرئيسية
الملخص EN
Purpose.
To report a new approach for removal of silicone oil.
Methods.
All surgeries were performed using 23-gauge vitrectomy system with two transconjunctival sutureless cannulas.
At the beginning, most of the silicone oil was removed by traditional microinvasive vitrectomy system through inferior-temporal cannula.
Then, the blood transfusion tube is removed from the inferior-temporal cannula, and the fluid-air exchange is performed.
A passive fluid-air exchange was performed to aspirate the residual silicone oil after gradually turning the patient’s head temporally by approximately 90° gradually.
Results.
After the surgery, all patients had a clear anterior chamber and vitreous cavity on slit lamp and B scan examination, respectively.
The mean time taken for silicone oil removal and total surgery was 8.0 ± 1.4 minutes and 12.4 ± 2.5 minutes, respectively.
The mean intraocular pressure 1 day, 3 days, 1 week, 1 month, and 3 months after surgery was 9.0 ± 5.8 mmHg, 11.3 ± 7.6 mmHg, 16.1 ± 6.9 mmHg, 17.7 ± 4.8 mmHg, and 17.1 ± 3.5 mmHg, respectively.
Conclusion.
This new approach may provide a safe and fast method to remove the silicone oil.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Lin, Zhong& Ke, Zhi Sheng& Zheng, Qian& Zhao, Zhen Quan& Song, Zong Ming. 2016. Passive Removal of Silicone Oil with Temporal Head Position through Two 23-Gauge Cannulas. Journal of Ophthalmology،Vol. 2016, no. 2016, pp.1-4.
https://search.emarefa.net/detail/BIM-1109955
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Lin, Zhong…[et al.]. Passive Removal of Silicone Oil with Temporal Head Position through Two 23-Gauge Cannulas. Journal of Ophthalmology No. 2016 (2016), pp.1-4.
https://search.emarefa.net/detail/BIM-1109955
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Lin, Zhong& Ke, Zhi Sheng& Zheng, Qian& Zhao, Zhen Quan& Song, Zong Ming. Passive Removal of Silicone Oil with Temporal Head Position through Two 23-Gauge Cannulas. Journal of Ophthalmology. 2016. Vol. 2016, no. 2016, pp.1-4.
https://search.emarefa.net/detail/BIM-1109955
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1109955
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)