Passive Removal of Silicone Oil with Temporal Head Position through Two 23-Gauge Cannulas
المؤلفون المشاركون
Lin, Zhong
Ke, Zhi Sheng
Zheng, Qian
Zhao, Zhen Quan
Song, Zong Ming
المصدر
العدد
المجلد 2016، العدد 2016 (31 ديسمبر/كانون الأول 2016)، ص ص. 1-4، 4ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2016-06-22
دولة النشر
مصر
عدد الصفحات
4
التخصصات الرئيسية
الملخص EN
Purpose.
To report a new approach for removal of silicone oil.
Methods.
All surgeries were performed using 23-gauge vitrectomy system with two transconjunctival sutureless cannulas.
At the beginning, most of the silicone oil was removed by traditional microinvasive vitrectomy system through inferior-temporal cannula.
Then, the blood transfusion tube is removed from the inferior-temporal cannula, and the fluid-air exchange is performed.
A passive fluid-air exchange was performed to aspirate the residual silicone oil after gradually turning the patient’s head temporally by approximately 90° gradually.
Results.
After the surgery, all patients had a clear anterior chamber and vitreous cavity on slit lamp and B scan examination, respectively.
The mean time taken for silicone oil removal and total surgery was 8.0 ± 1.4 minutes and 12.4 ± 2.5 minutes, respectively.
The mean intraocular pressure 1 day, 3 days, 1 week, 1 month, and 3 months after surgery was 9.0 ± 5.8 mmHg, 11.3 ± 7.6 mmHg, 16.1 ± 6.9 mmHg, 17.7 ± 4.8 mmHg, and 17.1 ± 3.5 mmHg, respectively.
Conclusion.
This new approach may provide a safe and fast method to remove the silicone oil.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Lin, Zhong& Ke, Zhi Sheng& Zheng, Qian& Zhao, Zhen Quan& Song, Zong Ming. 2016. Passive Removal of Silicone Oil with Temporal Head Position through Two 23-Gauge Cannulas. Journal of Ophthalmology،Vol. 2016, no. 2016, pp.1-4.
https://search.emarefa.net/detail/BIM-1109955
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Lin, Zhong…[et al.]. Passive Removal of Silicone Oil with Temporal Head Position through Two 23-Gauge Cannulas. Journal of Ophthalmology No. 2016 (2016), pp.1-4.
https://search.emarefa.net/detail/BIM-1109955
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Lin, Zhong& Ke, Zhi Sheng& Zheng, Qian& Zhao, Zhen Quan& Song, Zong Ming. Passive Removal of Silicone Oil with Temporal Head Position through Two 23-Gauge Cannulas. Journal of Ophthalmology. 2016. Vol. 2016, no. 2016, pp.1-4.
https://search.emarefa.net/detail/BIM-1109955
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1109955
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر