Purpose.

To report a new approach for removal of silicone oil.

Methods.

All surgeries were performed using 23-gauge vitrectomy system with two transconjunctival sutureless cannulas.

At the beginning, most of the silicone oil was removed by traditional microinvasive vitrectomy system through inferior-temporal cannula.

Then, the blood transfusion tube is removed from the inferior-temporal cannula, and the fluid-air exchange is performed.

A passive fluid-air exchange was performed to aspirate the residual silicone oil after gradually turning the patient’s head temporally by approximately 90° gradually.

Results.

After the surgery, all patients had a clear anterior chamber and vitreous cavity on slit lamp and B scan examination, respectively.

The mean time taken for silicone oil removal and total surgery was 8.0 ± 1.4 minutes and 12.4 ± 2.5 minutes, respectively.

The mean intraocular pressure 1 day, 3 days, 1 week, 1 month, and 3 months after surgery was 9.0 ± 5.8 mmHg, 11.3 ± 7.6 mmHg, 16.1 ± 6.9 mmHg, 17.7 ± 4.8 mmHg, and 17.1 ± 3.5 mmHg, respectively.

Conclusion.

This new approach may provide a safe and fast method to remove the silicone oil.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Lin, Zhong& Ke, Zhi Sheng& Zheng, Qian& Zhao, Zhen Quan& Song, Zong Ming. 2016. Passive Removal of Silicone Oil with Temporal Head Position through Two 23-Gauge Cannulas. Journal of Ophthalmology،Vol. 2016, no. 2016, pp.1-4.
https://search.emarefa.net/detail/BIM-1109955

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Lin, Zhong…[et al.]. Passive Removal of Silicone Oil with Temporal Head Position through Two 23-Gauge Cannulas. Journal of Ophthalmology No. 2016 (2016), pp.1-4.
https://search.emarefa.net/detail/BIM-1109955

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Lin, Zhong& Ke, Zhi Sheng& Zheng, Qian& Zhao, Zhen Quan& Song, Zong Ming. Passive Removal of Silicone Oil with Temporal Head Position through Two 23-Gauge Cannulas. Journal of Ophthalmology. 2016. Vol. 2016, no. 2016, pp.1-4.
https://search.emarefa.net/detail/BIM-1109955

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1109955