![](/images/graphics-bg.png)
Refractive Results: Safety and Efficacy of Secondary Piggyback Sensar™ AR40 Intraocular Lens Implantation to Correct Pseudophakic Refractive Error
المؤلفون المشاركون
Sayed, Khulood Mohammed
Hassan, Alahmady Hamad Alsmman
ElAgooz, Mohammed
Elhawary, Ashraf Mostafa
المصدر
العدد
المجلد 2016، العدد 2016 (31 ديسمبر/كانون الأول 2016)، ص ص. 1-5، 5ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2016-05-30
دولة النشر
مصر
عدد الصفحات
5
التخصصات الرئيسية
الملخص EN
In this study we evaluate the visual outcomes, safety, efficacy, and stability of implanting of second sulcus intraocular lens (IOL) to correct unsatisfied ametropic patients after phacoemulsification.
Methods.
Retrospective study of 15 eyes (15 patients) underwent secondary intraocular lens implanted into the ciliary sulcus.
The IOL used was a Sensar IOL three-piece foldable hydrophobic acrylic IOL.
The first IOL in all patients was acrylic intrabagal IOL implanted in uncomplicated phacoemulsification surgery.
Results.
Fifteen eyes (15 patients) were involved in this study.
Preoperatively, mean logMAR UDVA and CDVA were 0.88 ± 0.22 and 0.19 ± 0.13, respectively, with a mean follow-up of 28 months (range: 24 to 36 months).
At the end of the follow-up, all eyes achieved logMAR UDVA of 0.20 ± 0.12 with postoperative refraction ranging from 0.00 to −0.50 D of attempted emmetropia.
Conclusions.
Implantation of the second sulcus SensarAR40 IOL was found to be safe, easy, and simple technique for management of ametropia following uncomplicated phacoemulsification.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Hassan, Alahmady Hamad Alsmman& Sayed, Khulood Mohammed& ElAgooz, Mohammed& Elhawary, Ashraf Mostafa. 2016. Refractive Results: Safety and Efficacy of Secondary Piggyback Sensar™ AR40 Intraocular Lens Implantation to Correct Pseudophakic Refractive Error. Journal of Ophthalmology،Vol. 2016, no. 2016, pp.1-5.
https://search.emarefa.net/detail/BIM-1109963
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Hassan, Alahmady Hamad Alsmman…[et al.]. Refractive Results: Safety and Efficacy of Secondary Piggyback Sensar™ AR40 Intraocular Lens Implantation to Correct Pseudophakic Refractive Error. Journal of Ophthalmology No. 2016 (2016), pp.1-5.
https://search.emarefa.net/detail/BIM-1109963
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Hassan, Alahmady Hamad Alsmman& Sayed, Khulood Mohammed& ElAgooz, Mohammed& Elhawary, Ashraf Mostafa. Refractive Results: Safety and Efficacy of Secondary Piggyback Sensar™ AR40 Intraocular Lens Implantation to Correct Pseudophakic Refractive Error. Journal of Ophthalmology. 2016. Vol. 2016, no. 2016, pp.1-5.
https://search.emarefa.net/detail/BIM-1109963
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1109963
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)