Purpose.
To compare the final incision size and wound structure after the intraocular lens implantation from 2.0 mm transconjunctival single-plane sclerocorneal incision (TSSI) between the use of a motorized injector at first speed and the use of a manual injector.
Methods.
Patients were divided into three groups as follows: Group A, a manual injector, Group B, a motorized injector with 0.5 s pause time, and Group C, a motorized injector without pause time.
The change in incision size and anterior segment optical coherence tomography findings of the wound structure were analyzed.
Results.
110 eyes were enrolled (Group A: 40, Group B: 30, and Group C: 40).
The averaged change in incision size (mm) was 0.08, 0.01, and 0.03 in Groups A, B, and C, respectively (p<0.001).
The incision enlargement in Group A was statistically larger compared with other groups (p<0.01).
Descemet’s membrane detachments were seen in 26, 9, and 27 eyes one day after the surgery in Groups A, B, and C, respectively (p=0.001).
The rate of Descemet’s membrane detachment in Group B was significantly lower than other groups (p<0.01).
Conclusions.
The use of a motorized injector by fastest setting with 0.5 s pause time is the best for less wound damage in 2.0 mm TSSI.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Imai, Hisanori& Fujii, Ayaka& Tani, Emiko& Azumi, Atsushi. 2016. Wound Integrity of 2.0 mm Transconjunctival Single-Plane Sclerocorneal Incision: A Comparison between a Motorized Injector withwithout Pause Time and a Manual Injector. Journal of Ophthalmology،Vol. 2016, no. 2016, pp.1-5.
https://search.emarefa.net/detail/BIM-1110075
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Imai, Hisanori…[et al.]. Wound Integrity of 2.0 mm Transconjunctival Single-Plane Sclerocorneal Incision: A Comparison between a Motorized Injector withwithout Pause Time and a Manual Injector. Journal of Ophthalmology No. 2016 (2016), pp.1-5.
https://search.emarefa.net/detail/BIM-1110075
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Imai, Hisanori& Fujii, Ayaka& Tani, Emiko& Azumi, Atsushi. Wound Integrity of 2.0 mm Transconjunctival Single-Plane Sclerocorneal Incision: A Comparison between a Motorized Injector withwithout Pause Time and a Manual Injector. Journal of Ophthalmology. 2016. Vol. 2016, no. 2016, pp.1-5.
https://search.emarefa.net/detail/BIM-1110075
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1110075
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)