DNA Hybridization Detection Based on Resonance Frequency Readout in Graphene on Au SPR Biosensor
المؤلفون المشاركون
Hossain, Md. Biplob
Rana, Md. Masud
المصدر
العدد
المجلد 2016، العدد 2016 (31 ديسمبر/كانون الأول 2016)، ص ص. 1-7، 7ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2015-12-21
دولة النشر
مصر
عدد الصفحات
7
التخصصات الرئيسية
الملخص EN
This paper demonstrates a numerical modeling of surface plasmon resonance (SPR) biosensor for detecting DNA hybridization by recording the resonance frequency characteristics (RFC).
The proposed sensor is designed based on graphene material as biomolecular recognition elements (BRE) and the sharp SPR curve of gold (Au).
Numerical analysis shows that the variation of RFC for mismatched DNA strands is quiet negligible whereas that for complementary DNA strands is considerably countable.
Here, graphene is used to perform faster immobilization between target DNA and probe DNA.
The usage of graphene also changes the RFC that ensure hybridization of DNA event by utilizing its optochemical property.
In addition, proposed sensor successfully distinguishes between hybridization and single-nucleotide polymorphisms (SNP) by observing the variation level of RFC and maximum transmittance.
Therefore, the proposed frequency readout based SPR sensor could potentially open a new window of detection for biomolecular interactions.
We also highlight the advantage of using graphene sublayer by performing the sensitivity analysis.
Sandwiching of each graphene sublayer enhances 95% sensitivity comparing with conventional SPR sensor.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Hossain, Md. Biplob& Rana, Md. Masud. 2015. DNA Hybridization Detection Based on Resonance Frequency Readout in Graphene on Au SPR Biosensor. Journal of Sensors،Vol. 2016, no. 2016, pp.1-7.
https://search.emarefa.net/detail/BIM-1110535
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Hossain, Md. Biplob& Rana, Md. Masud. DNA Hybridization Detection Based on Resonance Frequency Readout in Graphene on Au SPR Biosensor. Journal of Sensors No. 2016 (2016), pp.1-7.
https://search.emarefa.net/detail/BIM-1110535
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Hossain, Md. Biplob& Rana, Md. Masud. DNA Hybridization Detection Based on Resonance Frequency Readout in Graphene on Au SPR Biosensor. Journal of Sensors. 2015. Vol. 2016, no. 2016, pp.1-7.
https://search.emarefa.net/detail/BIM-1110535
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1110535
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر