Sensor-Based Technique for Manually Scanned Hand-Held Optical Coherence Tomography Imaging

المؤلفون المشاركون

Pande, Paritosh
Monroy, Guillermo L.
Nolan, Ryan M.
Shelton, Ryan L.
Boppart, Stephen A.

المصدر

Journal of Sensors

العدد

المجلد 2016، العدد 2016 (31 ديسمبر/كانون الأول 2016)، ص ص. 1-7، 7ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2015-12-28

دولة النشر

مصر

عدد الصفحات

7

التخصصات الرئيسية

هندسة مدنية

الملخص EN

Hand-held optical coherence tomography (OCT) imaging probes offer flexibility to image sites that are otherwise challenging to access.

While the majority of hand-held imaging probes utilize galvanometer- or MEMS-scanning mirrors to transversely scan the imaging beam, these probes are commonly limited to lateral fields-of-view (FOV) of only a few millimeters.

The use of a freehand manually scanned probe can significantly increase the lateral FOV.

However, using the traditional fixed-rate triggering scheme for data acquisition in a manually scanned probe results in imaging artifacts due to variations in the scan velocity of the imaging probe.

These artifacts result in a structurally inaccurate image of the sample.

In this paper, we present a sensor-based manual scanning technique for OCT imaging, where real-time feedback from an optical motion sensor is used to trigger data acquisition.

This technique is able to circumvent the problem of motion artifacts during manual scanning by adaptively altering the trigger rate based on the instantaneous scan velocity, enabling OCT imaging over a large lateral FOV.

The feasibility of the proposed technique is demonstrated by imaging several biological and nonbiological samples.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Pande, Paritosh& Monroy, Guillermo L.& Nolan, Ryan M.& Shelton, Ryan L.& Boppart, Stephen A.. 2015. Sensor-Based Technique for Manually Scanned Hand-Held Optical Coherence Tomography Imaging. Journal of Sensors،Vol. 2016, no. 2016, pp.1-7.
https://search.emarefa.net/detail/BIM-1110634

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Pande, Paritosh…[et al.]. Sensor-Based Technique for Manually Scanned Hand-Held Optical Coherence Tomography Imaging. Journal of Sensors No. 2016 (2016), pp.1-7.
https://search.emarefa.net/detail/BIM-1110634

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Pande, Paritosh& Monroy, Guillermo L.& Nolan, Ryan M.& Shelton, Ryan L.& Boppart, Stephen A.. Sensor-Based Technique for Manually Scanned Hand-Held Optical Coherence Tomography Imaging. Journal of Sensors. 2015. Vol. 2016, no. 2016, pp.1-7.
https://search.emarefa.net/detail/BIM-1110634

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1110634