Base Isolation for Seismic Retrofitting of a Multiple Building Structure: Evaluation of Equivalent Linearization Method

المؤلفون المشاركون

Ferraioli, Massimiliano
Mandara, Alberto

المصدر

Mathematical Problems in Engineering

العدد

المجلد 2016، العدد 2016 (31 ديسمبر/كانون الأول 2016)، ص ص. 1-17، 17ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2016-12-20

دولة النشر

مصر

عدد الصفحات

17

التخصصات الرئيسية

هندسة مدنية

الملخص EN

Although the most commonly used isolation systems exhibit nonlinear inelastic behaviour, the equivalent linear elastic analysis is commonly used in the design and assessment of seismic-isolated structures.

The paper investigates if the linear elastic model is suitable for the analysis of a seismically isolated multiple building structure.

To this aim, its computed responses were compared with those calculated by nonlinear dynamic analysis.

A common base isolation plane connects the isolation bearings supporting the adjacent structures.

In this situation, the conventional equivalent linear elastic analysis may have some problems of accuracy because this method is calibrated on single base-isolated structures.

Moreover, the torsional characteristics of the combined system are significantly different from those of separate isolated buildings.

A number of numerical simulations and parametric studies under earthquake excitations were performed.

The accuracy of the dynamic response obtained by the equivalent linear elastic model was calculated by the magnitude of the error with respect to the corresponding response considering the nonlinear behaviour of the isolation system.

The maximum displacements at the isolation level, the maximum interstorey drifts, and the peak absolute acceleration were selected as the most important response measures.

The influence of mass eccentricity, torsion, and high-modes effects was finally investigated.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Ferraioli, Massimiliano& Mandara, Alberto. 2016. Base Isolation for Seismic Retrofitting of a Multiple Building Structure: Evaluation of Equivalent Linearization Method. Mathematical Problems in Engineering،Vol. 2016, no. 2016, pp.1-17.
https://search.emarefa.net/detail/BIM-1112767

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Ferraioli, Massimiliano& Mandara, Alberto. Base Isolation for Seismic Retrofitting of a Multiple Building Structure: Evaluation of Equivalent Linearization Method. Mathematical Problems in Engineering No. 2016 (2016), pp.1-17.
https://search.emarefa.net/detail/BIM-1112767

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Ferraioli, Massimiliano& Mandara, Alberto. Base Isolation for Seismic Retrofitting of a Multiple Building Structure: Evaluation of Equivalent Linearization Method. Mathematical Problems in Engineering. 2016. Vol. 2016, no. 2016, pp.1-17.
https://search.emarefa.net/detail/BIM-1112767

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1112767