![](/images/graphics-bg.png)
CMM-Based Volumetric Assessment Methodology for Polyethylene Tibial Knee Inserts in Total Knee Replacement
المؤلفون المشاركون
Jiang, Wei
Ji, Cuicui
Jin, Zhongmin
Dai, Yuntian
المصدر
Applied Bionics and Biomechanics
العدد
المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-6، 6ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2018-04-10
دولة النشر
مصر
عدد الصفحات
6
التخصصات الرئيسية
الملخص EN
Total knee replacement is a common surgical procedure in orthopaedics.
Accurate volumetric wear assessment of the polyethylene knee inserts has been an essential subject for improving the longevity.
A new CMM-based methodology was presented to determine volumetric material loss based on curve surface fitting without prewear data, CAD model, or original design of drawings.
Both computational and experimental simulated volume removal tests were run to validate the methodology by comparing with the gravimetric measurements.
The volume and linear wear of the tibial inserts were calculated using the presented method based on the coordinates acquired by the CMM.
The results indicate that the methodology is adequate for clinically retrieved tibial inserts where no prewear data are provided.
This technique can also be used for biotribological study of other polyethylene components, since wear and damage can be assessed visually and volumetrically.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Jiang, Wei& Ji, Cuicui& Jin, Zhongmin& Dai, Yuntian. 2018. CMM-Based Volumetric Assessment Methodology for Polyethylene Tibial Knee Inserts in Total Knee Replacement. Applied Bionics and Biomechanics،Vol. 2018, no. 2018, pp.1-6.
https://search.emarefa.net/detail/BIM-1114896
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Jiang, Wei…[et al.]. CMM-Based Volumetric Assessment Methodology for Polyethylene Tibial Knee Inserts in Total Knee Replacement. Applied Bionics and Biomechanics No. 2018 (2018), pp.1-6.
https://search.emarefa.net/detail/BIM-1114896
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Jiang, Wei& Ji, Cuicui& Jin, Zhongmin& Dai, Yuntian. CMM-Based Volumetric Assessment Methodology for Polyethylene Tibial Knee Inserts in Total Knee Replacement. Applied Bionics and Biomechanics. 2018. Vol. 2018, no. 2018, pp.1-6.
https://search.emarefa.net/detail/BIM-1114896
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1114896
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)