An Experimental Study of Horizontal Bearing Capacity of Vertical Steel Floral Tube Micropiles with Double Grouting

المؤلفون المشاركون

Wang, Kaiyang
Shang, Yanjun

المصدر

Advances in Civil Engineering

العدد

المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-11، 11ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2018-11-25

دولة النشر

مصر

عدد الصفحات

11

التخصصات الرئيسية

هندسة مدنية

الملخص EN

This paper examines the performance of a novel technology, vertical steel floral tube micropiles with double grouting.

It is the combination of micropile technology and double grouting technology.

A large-scale model tank was applied to impart horizontal bearing capacity, and the slope soil pressure and flexural performance of the micropile were investigated under four experimental conditions.

The peak grouting pressure during the double grouting process was defined as the fracturing pressure of the double grouting, and it was positively correlated to the interval time between first grouting and secondary grouting.

Compared with traditional grouting, double grouting increased the horizontal bearing capacity of the single micropile with the vertical steel floral tube by 24.42%.

The horizontal bearing capacity was also 20.25% higher for the structure with three micropiles, compared with a 3-fold value of horizontal sliding resistance.

In the test, the maximum bending moment acting on the pile above the sliding surface was located 2.0–2.5 m away from the pile top, and the largest negative bending moment acting on the pile below the slip surface was located 4.0 m away from the pile top.

The ultimate bending moment of the single pile increased by 12.8 kN·m with double grouting, and the bending resistance increased by 96.2%.

The experimental results showed that the double grouting technology significantly improved the horizontal bearing capacity of the micropile with the steel floral tube, and the soil reinforcement performance between piles was more pronounced.

Also, the shear capacity and the flexural capacity were significantly improved compared with the original technology.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Wang, Kaiyang& Shang, Yanjun. 2018. An Experimental Study of Horizontal Bearing Capacity of Vertical Steel Floral Tube Micropiles with Double Grouting. Advances in Civil Engineering،Vol. 2018, no. 2018, pp.1-11.
https://search.emarefa.net/detail/BIM-1116702

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Wang, Kaiyang& Shang, Yanjun. An Experimental Study of Horizontal Bearing Capacity of Vertical Steel Floral Tube Micropiles with Double Grouting. Advances in Civil Engineering No. 2018 (2018), pp.1-11.
https://search.emarefa.net/detail/BIM-1116702

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Wang, Kaiyang& Shang, Yanjun. An Experimental Study of Horizontal Bearing Capacity of Vertical Steel Floral Tube Micropiles with Double Grouting. Advances in Civil Engineering. 2018. Vol. 2018, no. 2018, pp.1-11.
https://search.emarefa.net/detail/BIM-1116702

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1116702