Comparison of Modified Cartilage Shield Tympanoplasty with Tympanoplasty Using Temporalis Fascia Only: Retrospective Analysis of 142 Cases

المؤلفون المشاركون

Vadiya, Sohil
Parikh, Vibhuti
Shah, Saumya
Pandya, Parita
Kansara, Anuj

المصدر

Scientifica

العدد

المجلد 2016، العدد 2016 (31 ديسمبر/كانون الأول 2016)، ص ص. 1-4، 4ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2016-07-31

دولة النشر

مصر

عدد الصفحات

4

التخصصات الرئيسية

الأمراض

الملخص EN

The current study compares outcomes of modified cartilage shield tympanoplasty (CST) with temporalis fascia tympanoplasty in type I procedures in Indian patients.

Graft uptake rates are better with the CST technique and hearing results are almost equivalent with both techniques except at 8000 Hz where improvement in hearing was found better with the use of temporalis fascia alone.

The CST technique used in the study is unique.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Vadiya, Sohil& Parikh, Vibhuti& Shah, Saumya& Pandya, Parita& Kansara, Anuj. 2016. Comparison of Modified Cartilage Shield Tympanoplasty with Tympanoplasty Using Temporalis Fascia Only: Retrospective Analysis of 142 Cases. Scientifica،Vol. 2016, no. 2016, pp.1-4.
https://search.emarefa.net/detail/BIM-1117897

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Vadiya, Sohil…[et al.]. Comparison of Modified Cartilage Shield Tympanoplasty with Tympanoplasty Using Temporalis Fascia Only: Retrospective Analysis of 142 Cases. Scientifica No. 2016 (2016), pp.1-4.
https://search.emarefa.net/detail/BIM-1117897

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Vadiya, Sohil& Parikh, Vibhuti& Shah, Saumya& Pandya, Parita& Kansara, Anuj. Comparison of Modified Cartilage Shield Tympanoplasty with Tympanoplasty Using Temporalis Fascia Only: Retrospective Analysis of 142 Cases. Scientifica. 2016. Vol. 2016, no. 2016, pp.1-4.
https://search.emarefa.net/detail/BIM-1117897

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1117897