![](/images/graphics-bg.png)
Dimensional Variations of Left-Sided Double-Lumen Endobronchial Tubes
المؤلفون المشاركون
Hegland, Niels
Schnitzler, Sebastian
Ellensohn, Jan
Steurer, Marc P.
Weiss, Markus
Dullenkopf, Alexander
المصدر
Anesthesiology Research and Practice
العدد
المجلد 2019، العدد 2019 (31 ديسمبر/كانون الأول 2019)، ص ص. 1-9، 9ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2019-09-24
دولة النشر
مصر
عدد الصفحات
9
التخصصات الرئيسية
الملخص EN
Background.
Tube size selection is critical in ventilating patients’ lungs using double-lumen endobronchial tubes (DLTs).
Little information about relevant parameters is readily available from manufacturers.
The aim of this study is to provide reference data for relevant dimensions of conventionally available DLTs.
Methods.
In this study in a benchmark in vitro setup, several dimensional parameters of four sizes of left-sided double-lumen endobronchial tubes from six different manufacturers were assessed, such as distances and diameters of tube shaft, cuff lengths, and diameters as well the angle at the tip.
Results.
Endobronchial tubes of ostensibly the same size revealed wide variation in measured parameters between brands from different manufacturers.
In some parameters, there was an overlap between different sizes from the same manufacturer, i.e., diameters and distances did not increase with increasing nominal endobronchial tube size.
The information about dimensions of endobronchial tubes provided by manufacturers’ leaflets is insufficient.
Conclusions.
Endobronchial tube size selection carries unnecessary uncertainty because clinically relevant parameters are unknown and vary considerably between different manufacturers.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Hegland, Niels& Schnitzler, Sebastian& Ellensohn, Jan& Steurer, Marc P.& Weiss, Markus& Dullenkopf, Alexander. 2019. Dimensional Variations of Left-Sided Double-Lumen Endobronchial Tubes. Anesthesiology Research and Practice،Vol. 2019, no. 2019, pp.1-9.
https://search.emarefa.net/detail/BIM-1122283
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Hegland, Niels…[et al.]. Dimensional Variations of Left-Sided Double-Lumen Endobronchial Tubes. Anesthesiology Research and Practice No. 2019 (2019), pp.1-9.
https://search.emarefa.net/detail/BIM-1122283
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Hegland, Niels& Schnitzler, Sebastian& Ellensohn, Jan& Steurer, Marc P.& Weiss, Markus& Dullenkopf, Alexander. Dimensional Variations of Left-Sided Double-Lumen Endobronchial Tubes. Anesthesiology Research and Practice. 2019. Vol. 2019, no. 2019, pp.1-9.
https://search.emarefa.net/detail/BIM-1122283
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1122283
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)