الملخص EN
This study introduces an eddy current thermography technique that can be used to detect and evaluate steel corrosion in a reinforced concrete structure.
The rate of surface temperature changes in reinforced concrete is proposed as a means to characterize the degree of steel bar corrosion.
The rate of surface temperature changes increased gradually with an increase in the corrosion degree.
The influence of structural parameters on the rate of the temperature change was analyzed in detail.
The results indicated that the rate of surface temperature change increased with a decrease in the concrete cover depth and with an increase in the humidity of the concrete, and this was affected by the diameter of the internal steel bar.
Concrete cover was the most significant factor that affected the rate of the surface temperature change, except for the corrosion degree.
The variations in the surface temperature of reinforced concrete can be explained using the law of electromagnetic induction and the electrochemical property change of corroded steel bar.
This research provides a reliable basis for real-world applications and is helpful to understand the application scope of eddy current thermography technology for the quantitative detection of steel corrosion.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Liu, Lu& Zheng, Dan& Zhou, Jianting& Yang, Juan& Zhang, Hong. 2020. Parameters That Influence Corrosion Detection in Reinforced Concrete Based on Eddy Current Thermography. Advances in Civil Engineering،Vol. 2020, no. 2020, pp.1-9.
https://search.emarefa.net/detail/BIM-1122816
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Liu, Lu…[et al.]. Parameters That Influence Corrosion Detection in Reinforced Concrete Based on Eddy Current Thermography. Advances in Civil Engineering No. 2020 (2020), pp.1-9.
https://search.emarefa.net/detail/BIM-1122816
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Liu, Lu& Zheng, Dan& Zhou, Jianting& Yang, Juan& Zhang, Hong. Parameters That Influence Corrosion Detection in Reinforced Concrete Based on Eddy Current Thermography. Advances in Civil Engineering. 2020. Vol. 2020, no. 2020, pp.1-9.
https://search.emarefa.net/detail/BIM-1122816
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1122816
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر