Relationship between Crystalline Lens Thickness and Shape and the Identification of Anterior Ocular Segment Parameters for Predicting the Intraocular Lens Position after Cataract Surgery

المؤلفون المشاركون

Igarashi, Akihito
Shimizu, Kimiya
Satou, Tsukasa
Tsunehiro, Shuntaro
Kato, Sayaka
Koshimizu, Manabu
Niida, Takahiro

المصدر

BioMed Research International

العدد

المجلد 2019، العدد 2019 (31 ديسمبر/كانون الأول 2019)، ص ص. 1-9، 9ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2019-07-08

دولة النشر

مصر

عدد الصفحات

9

التخصصات الرئيسية

الطب البشري

الملخص EN

Purpose.

This study was performed to investigate the relationships among crystalline lens shape, actual intraocular lens (IOL) position, and crystalline lens thickness (LT), as measured by anterior segment optical coherence tomography (AS-OCT), and to determine anterior ocular segment parameters that predict postoperative IOL position.

Methods.

Seventy-nine eyes of 79 patients who underwent uneventful cataract surgery were enrolled.

For crystalline lens preoperative anterior segment data, the LT, and anterior, equatorial, and posterior surface depths (ASD, ESD, and PSD, respectively) of crystalline lenses were quantitatively determined.

For postoperative anterior segment data, the actual IOL position was quantified.

Moreover, the following correlations were analyzed: LT with the ASD, ESD, PSD, and IOL position; IOL position with the ASD, ESD, and PSD; and refractive prediction error with the difference between the predicted postoperative anterior chamber depth (ACD) of the SRK/T formula and the IOL position, ASD, ESD, and PSD (each depth minus the predicted postoperative ACD of the SRK/T formula).

Results.

The LT was significantly correlated with the ASD (r = -0.65) and PSD (r = 0.41), whereas it was not correlated with the ESD or IOL position.

The IOL position was significantly correlated with the ASD (r = 0.67), ESD (r = 0.72), and PSD (r = 0.74).

The refractive prediction error was significantly correlated with the difference between the predicted postoperative ACD of the SRK/T formula and the IOL position (r = 0.65), ASD (r = 0.46), ESD (r = 0.54), and PSD (r = 0.58).

Conclusions.

The ESD and PSD obtained using AS-OCT were highly correlated with the IOL position and significantly correlated with the refractive prediction error.

These findings suggest that the ESD and PSD may enhance the accuracy of actual IOL position prediction.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Satou, Tsukasa& Shimizu, Kimiya& Tsunehiro, Shuntaro& Igarashi, Akihito& Kato, Sayaka& Koshimizu, Manabu…[et al.]. 2019. Relationship between Crystalline Lens Thickness and Shape and the Identification of Anterior Ocular Segment Parameters for Predicting the Intraocular Lens Position after Cataract Surgery. BioMed Research International،Vol. 2019, no. 2019, pp.1-9.
https://search.emarefa.net/detail/BIM-1124583

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Satou, Tsukasa…[et al.]. Relationship between Crystalline Lens Thickness and Shape and the Identification of Anterior Ocular Segment Parameters for Predicting the Intraocular Lens Position after Cataract Surgery. BioMed Research International No. 2019 (2019), pp.1-9.
https://search.emarefa.net/detail/BIM-1124583

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Satou, Tsukasa& Shimizu, Kimiya& Tsunehiro, Shuntaro& Igarashi, Akihito& Kato, Sayaka& Koshimizu, Manabu…[et al.]. Relationship between Crystalline Lens Thickness and Shape and the Identification of Anterior Ocular Segment Parameters for Predicting the Intraocular Lens Position after Cataract Surgery. BioMed Research International. 2019. Vol. 2019, no. 2019, pp.1-9.
https://search.emarefa.net/detail/BIM-1124583

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1124583