Quantitative Analysis of Apatite Formation on Titanium and Zirconia in a Simulated Body Fluid Solution Using the Quartz Crystal Microbalance Method

المؤلفون المشاركون

Hayakawa, Tohru
Yoshida, Eiji

المصدر

Advances in Materials Science and Engineering

العدد

المجلد 2017، العدد 2017 (31 ديسمبر/كانون الأول 2017)، ص ص. 1-9، 9ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2017-04-02

دولة النشر

مصر

عدد الصفحات

9

الملخص EN

The bone-bonding ability of a material is evaluated by examining apatite formation on its surface in simulated body fluid (SBF).

Partially stabilized zirconia (ZrO2) is currently attractive as an alternative to titanium (Ti) implants; however, no quantitative analysis of apatite formation between Ti and ZrO2 in SBF has been reported.

In the present study, we quantitatively evaluated apatite formation onto Ti or ZrO2 in SBF using the 27 MHz quartz crystal microbalance method (QCM).

In the QCM measurements, apatite formation was detected as a frequency decrease in the Ti or ZrO2 sensor.

Frequency decreases were observed at around 1 hour for Ti and at around 2 hours for the ZrO2 sensor after the injection of SBF.

This revealed that the Ti sensor showed faster apatite formation than ZrO2.

There was no significant difference in the amounts of apatite formation between the Ti and ZrO2 sensors after 24 hours of apatite formation in SBF.

In conclusion, the present quantitative study using QCM revealed that apatite formation on the Ti surface in the SBF was obviously faster than that on the ZrO2 surface.

Faster apatite formation may predict faster initiation of bone formation on Ti compared with ZrO2.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Yoshida, Eiji& Hayakawa, Tohru. 2017. Quantitative Analysis of Apatite Formation on Titanium and Zirconia in a Simulated Body Fluid Solution Using the Quartz Crystal Microbalance Method. Advances in Materials Science and Engineering،Vol. 2017, no. 2017, pp.1-9.
https://search.emarefa.net/detail/BIM-1124771

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Yoshida, Eiji& Hayakawa, Tohru. Quantitative Analysis of Apatite Formation on Titanium and Zirconia in a Simulated Body Fluid Solution Using the Quartz Crystal Microbalance Method. Advances in Materials Science and Engineering No. 2017 (2017), pp.1-9.
https://search.emarefa.net/detail/BIM-1124771

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Yoshida, Eiji& Hayakawa, Tohru. Quantitative Analysis of Apatite Formation on Titanium and Zirconia in a Simulated Body Fluid Solution Using the Quartz Crystal Microbalance Method. Advances in Materials Science and Engineering. 2017. Vol. 2017, no. 2017, pp.1-9.
https://search.emarefa.net/detail/BIM-1124771

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1124771