The Effect of Tracheal Intubation-Induced Autonomic Response on Photoplethysmography
المؤلف
المصدر
Anesthesiology Research and Practice
العدد
المجلد 2017، العدد 2017 (31 ديسمبر/كانون الأول 2017)، ص ص. 1-5، 5ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2017-04-02
دولة النشر
مصر
عدد الصفحات
5
التخصصات الرئيسية
الملخص EN
Introduction.
Intraoperative stress responses and postoperative pain can be monitored using photoplethysmography (PPG).
PPG signal has two components, AC and DC.
Effects of noxious stimuli-induced stress responses have not been studied on the DC component of PPG.
The aim of this study was to investigate the effect of a known noxious stimulus (endotracheal intubation) on both the AC and DC components of PPG.
Methods.
15 surgical patients having general anesthesia were enrolled into this clinical study.
PPG was recorded electronically from a pulse oximeter.
Maximum changes in the AC and DC components of the PPG and pulse rate were determined in response to endotracheal intubation from high frequency (62.5 Hz) PPG recordings.
Results.
Endotracheal intubation-induced autonomic stress response resulted in a significant decrease in the AC component of the PPG and an increase in pulse rate in every subject (p<0.05 for all).
The decrease in the AC component of the PPG was 50±12% (p<0.05) and the increase in pulse rate was 26±10 bpm (p<0.05).
The response of the DC component was variable (p = NS).
Conclusion.
Endotracheal intubation-induced stress response resulted in a significant and consistent change in the AC, but not the DC component of the PPG.
This trial is registered with ClinicalTrials.gov Identifier NCT03032939.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Talke, Pekka. 2017. The Effect of Tracheal Intubation-Induced Autonomic Response on Photoplethysmography. Anesthesiology Research and Practice،Vol. 2017, no. 2017, pp.1-5.
https://search.emarefa.net/detail/BIM-1125519
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Talke, Pekka. The Effect of Tracheal Intubation-Induced Autonomic Response on Photoplethysmography. Anesthesiology Research and Practice No. 2017 (2017), pp.1-5.
https://search.emarefa.net/detail/BIM-1125519
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Talke, Pekka. The Effect of Tracheal Intubation-Induced Autonomic Response on Photoplethysmography. Anesthesiology Research and Practice. 2017. Vol. 2017, no. 2017, pp.1-5.
https://search.emarefa.net/detail/BIM-1125519
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1125519
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر