Clinical Course of Dual-Chamber Implantable Cardioverter-Defibrillator Recipients followed by Cardiac Remote Monitoring: Insights from the LION Registry
المؤلفون المشاركون
Schwab, Joerg O.
Nägele, Herbert
Oswald, Hanno
Klein, Gunnar
Gunkel, Oliver
Lang, Andreas
Bauer, Wolfgang R.
Korb, Paul
Hauser, Tino
المصدر
العدد
المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-8، 8ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2018-11-04
دولة النشر
مصر
عدد الصفحات
8
التخصصات الرئيسية
الملخص EN
Patients receiving dual-chamber implantable cardioverter-defibrillator (DR-ICD) therapy are at risk of developing atrial arrhythmia because of the increased rate of ventricular pacing and the progression of heart failure.
Remote monitoring (RM) may identify the patients at highest risk of adverse events such as atrial arrhythmias.
A total of 283 patients with 91,632 remote transmissions during a 15-month follow-up (FU) period enrolled in the LION registry were analysed.
The parameters retrieved included the pacing mode, lower rate limit, percentage of atrial (%AP) and ventricular pacing (%VP), and percentage of atrial arrhythmia burden (%AB).
In 92.7% of patients, the devices were initially programmed in DDD(R) or DDI(R), with changes of the pacing mode in 19.3% only.
The lower rate limit remained stable in 80.4% of patients.
At the first transmission, 8.7% of patients suffered from RM-detected atrial arrhythmia, which reached 36% during FU.
The %AP was not associated with increased AB (p = 0.67), but the %VP was different in patients developing RM-detected atrial arrhythmia (26.9% vs.
13.7%, p < 0.00001).
The %VP increased in 105 patients (significance level of α = 0.05), and 11 patients crossed the border of 50% VP.
The LION substudy supports the concept of using RM in a real-world DR-ICD population.
Remote monitoring of DR-ICDs allows for the quantification of the course of the pacing parameters and AB.
Based on these observations, device parameters can be adjusted and optimized.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Schwab, Joerg O.& Nägele, Herbert& Oswald, Hanno& Klein, Gunnar& Gunkel, Oliver& Lang, Andreas…[et al.]. 2018. Clinical Course of Dual-Chamber Implantable Cardioverter-Defibrillator Recipients followed by Cardiac Remote Monitoring: Insights from the LION Registry. BioMed Research International،Vol. 2018, no. 2018, pp.1-8.
https://search.emarefa.net/detail/BIM-1125639
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Schwab, Joerg O.…[et al.]. Clinical Course of Dual-Chamber Implantable Cardioverter-Defibrillator Recipients followed by Cardiac Remote Monitoring: Insights from the LION Registry. BioMed Research International No. 2018 (2018), pp.1-8.
https://search.emarefa.net/detail/BIM-1125639
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Schwab, Joerg O.& Nägele, Herbert& Oswald, Hanno& Klein, Gunnar& Gunkel, Oliver& Lang, Andreas…[et al.]. Clinical Course of Dual-Chamber Implantable Cardioverter-Defibrillator Recipients followed by Cardiac Remote Monitoring: Insights from the LION Registry. BioMed Research International. 2018. Vol. 2018, no. 2018, pp.1-8.
https://search.emarefa.net/detail/BIM-1125639
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1125639
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر