Application of 3D-Printed Personalized Guide in Arthroscopic Ankle Arthrodesis
المؤلفون المشاركون
Duan, Xiaojun
He, Peng
Fan, Huaquan
Zhang, Chengchang
Wang, Fuyou
Yang, Liu
المصدر
العدد
المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-8، 8ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2018-09-12
دولة النشر
مصر
عدد الصفحات
8
التخصصات الرئيسية
الملخص EN
Objective.
To accurately drill the Kirschner wire with the help of the 3D-printed personalized guide and to evaluate the feasibility of the 3D technology as well as the outcome of the surgery.
Methods.
Patients’ DICM data of ankle via CT examinations were introduced into the MIMICS software to design the personalized guides.
Two 2mm Kirschner wires were drilled with the help of the guides; the C-arm fluoroscopy was used to confirm the position of the wires before applying the cannulated screws.
The patients who underwent ankle arthrodesis were divided into two groups.
The experimental group adopted the 3D-printed personalized guides, while the control group received traditional method, i.e., drilling the Kirschner wires according to the surgeon’s previous experience.
The times of completing drilling the Kirschner wires to correct position were compared between the two groups.
Regular follow-ups were conducted to statistically analyze the differences in the ankle fusion time and AOFAS scores between the two groups.
Results.
3D-printed personalized guides were successfully prepared.
A total of 29 patients were enrolled, 15 in the experimental group and 14 in the control group.
It took 2.2 ± 0.8 minutes to drill the Kirschner wires to correct position in the experimental group and 4.5 ± 1.6 minutes in the control group (p=0.001).
No obvious complications occurred in the two groups during and after surgery.
Postoperative radiographs confirmed bony fusion in all cases.
There were no significant differences in the fusion time (p=0.82) and AOFAS scores at 1 year postoperatively between the two groups (p=0.55).
Conclusions.
The application of 3D-printed personalized guide in assisting the accurate drilling of Kirschner wire in ankle arthrodesis can shorten the operation time and reduce the intraoperative radiation.
This technique does not affect the surgical outcome.
Trial Registration Number.
This study is registered on www.clinicaltrials.gov with NCT03626935.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Duan, Xiaojun& He, Peng& Fan, Huaquan& Zhang, Chengchang& Wang, Fuyou& Yang, Liu. 2018. Application of 3D-Printed Personalized Guide in Arthroscopic Ankle Arthrodesis. BioMed Research International،Vol. 2018, no. 2018, pp.1-8.
https://search.emarefa.net/detail/BIM-1125890
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Duan, Xiaojun…[et al.]. Application of 3D-Printed Personalized Guide in Arthroscopic Ankle Arthrodesis. BioMed Research International No. 2018 (2018), pp.1-8.
https://search.emarefa.net/detail/BIM-1125890
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Duan, Xiaojun& He, Peng& Fan, Huaquan& Zhang, Chengchang& Wang, Fuyou& Yang, Liu. Application of 3D-Printed Personalized Guide in Arthroscopic Ankle Arthrodesis. BioMed Research International. 2018. Vol. 2018, no. 2018, pp.1-8.
https://search.emarefa.net/detail/BIM-1125890
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1125890
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر