Using a Dielectric Capacitance Cell to Determine the Dielectric Properties of Pure Sand Artificially Contaminated with Pb, Cd, Fe, and Zn

المؤلفون المشاركون

Dahim, Mohammed
Abuaddous, Musab
Ismail, Rabah
Al-Mattarneh, Hashem
Jaradat, Aiman

المصدر

Applied and Environmental Soil Science

العدد

المجلد 2020، العدد 2020 (31 ديسمبر/كانون الأول 2020)، ص ص. 1-10، 10ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2020-12-14

دولة النشر

مصر

عدد الصفحات

10

التخصصات الرئيسية

علم الأرض والمياه والبيئة

الملخص EN

This paper presents a new method of dielectric capacitance cell as a proposed device for measuring the impedance of pure sand artificially contaminated with four heavy metals.

Dielectric constant and loss factor of clean and contaminated sand at various levels were calculated from the measured sand impedances.

The advantages and benefits of using the proposed dielectric capacitance cell were its low cost, simple calculation, calibration procedures, portable and lightweight, and easy to modify the electrodes to suit testing in the field.

Pure sand was saturated with water artificially polluted in the lab with Pb, Cd, Fe, and Zn at heavy metal contents 0, 7.5, 15, 22.5, and 30 mg/kg of sand.

The dielectric properties of polluted sand were evaluated at a frequency range from 100 kHz to 1000 kHz.

The polluted sand exhibit different dielectric constants and loss factors from the unpolluted sand.

The results also indicate that the dielectric constant decreases with increasing pollution level for all heavy metals.

This may attribute to the polarization mechanism change with existing heavy metal.

The loss factor of sand increases with the increasing pollution level.

This may be explained by the increase of ionic conductivity of pore water with heavy metal in the sand.

Sand polluted with heavy metal with higher resistivity and density possess a higher dielectric constant and lower loss factor than other polluted metals.

Evaluation of the dielectric characteristics of polluted sand could have the potential to monitor heavy metal pollution.

Even with promising results obtained with the proposed dielectric device, it is necessary to explore several other factors affecting the measurements such as sand water content, soil texture, and type of soil.

Also, testing polluted soil near industrial pollution is needed.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Dahim, Mohammed& Abuaddous, Musab& Ismail, Rabah& Al-Mattarneh, Hashem& Jaradat, Aiman. 2020. Using a Dielectric Capacitance Cell to Determine the Dielectric Properties of Pure Sand Artificially Contaminated with Pb, Cd, Fe, and Zn. Applied and Environmental Soil Science،Vol. 2020, no. 2020, pp.1-10.
https://search.emarefa.net/detail/BIM-1126340

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Dahim, Mohammed…[et al.]. Using a Dielectric Capacitance Cell to Determine the Dielectric Properties of Pure Sand Artificially Contaminated with Pb, Cd, Fe, and Zn. Applied and Environmental Soil Science No. 2020 (2020), pp.1-10.
https://search.emarefa.net/detail/BIM-1126340

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Dahim, Mohammed& Abuaddous, Musab& Ismail, Rabah& Al-Mattarneh, Hashem& Jaradat, Aiman. Using a Dielectric Capacitance Cell to Determine the Dielectric Properties of Pure Sand Artificially Contaminated with Pb, Cd, Fe, and Zn. Applied and Environmental Soil Science. 2020. Vol. 2020, no. 2020, pp.1-10.
https://search.emarefa.net/detail/BIM-1126340

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1126340