![](/images/graphics-bg.png)
The Fluid Dynamical Performance of the Carpentier-Edwards PERIMOUNT Magna Ease Prosthesis
المؤلفون المشاركون
Wendt, Daniel
Marx, Philipp
Kowalczyk, Wojciech
Demircioglu, Aydin
Brault, Gary Neil
Wendt, Hermann
Shehada, Sharaf-Eldin
El Gabry, Mohamed
Tsagakis, Konstantinos
Jakob, Heinz
المصدر
العدد
المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-9، 9ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2018-01-10
دولة النشر
مصر
عدد الصفحات
9
التخصصات الرئيسية
الملخص EN
The aim of the present in vitro study was the evaluation of the fluid dynamical performance of the Carpentier-Edwards PERIMOUNT Magna Ease depending on the prosthetic size (21, 23, and 25 mm) and the cardiac output (3.6–6.4 L/min).
A self-constructed flow channel in combination with particle image velocimetry (PIV) enabled precise results with high reproducibility, focus on maximal and local peek velocities, strain, and velocity gradients.
These flow parameters allow insights into the generation of forces that act on blood cells and the aortic wall.
The results showed that the 21 and 23 mm valves have a quite similar performance.
Maximal velocities were 3.03±0.1 and 2.87±0.13 m/s; maximal strain Exx, 913.81±173.25 and 896.15±88.16 1/s; maximal velocity gradient Eyx, 1203.14±221.84 1/s and 1200.81±61.83 1/s.
The 25 mm size revealed significantly lower values: maximal velocity, 2.47±0.15 m/s; maximal strain Exx, 592.98±155.80 1/s; maximal velocity gradient Eyx, 823.71±38.64 1/s.
In summary, the 25 mm Magna Ease was able to create a wider, more homogenous flow with lower peak velocities especially for higher flow rates.
Despite the wider flow, the velocity values close to the aortic walls did not exceed the level of the smaller valves.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Marx, Philipp& Kowalczyk, Wojciech& Demircioglu, Aydin& Brault, Gary Neil& Wendt, Hermann& Shehada, Sharaf-Eldin…[et al.]. 2018. The Fluid Dynamical Performance of the Carpentier-Edwards PERIMOUNT Magna Ease Prosthesis. BioMed Research International،Vol. 2018, no. 2018, pp.1-9.
https://search.emarefa.net/detail/BIM-1127294
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Marx, Philipp…[et al.]. The Fluid Dynamical Performance of the Carpentier-Edwards PERIMOUNT Magna Ease Prosthesis. BioMed Research International No. 2018 (2018), pp.1-9.
https://search.emarefa.net/detail/BIM-1127294
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Marx, Philipp& Kowalczyk, Wojciech& Demircioglu, Aydin& Brault, Gary Neil& Wendt, Hermann& Shehada, Sharaf-Eldin…[et al.]. The Fluid Dynamical Performance of the Carpentier-Edwards PERIMOUNT Magna Ease Prosthesis. BioMed Research International. 2018. Vol. 2018, no. 2018, pp.1-9.
https://search.emarefa.net/detail/BIM-1127294
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1127294
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)