Peri-Implant Bone Behavior after Single Drill versus Multiple Sequence for Osteotomy Drill
المؤلفون المشاركون
Gehrke, S. A.
Shibli, Jamil Awad
Prados-Frutos, Juan Carlos
Bettach, Raphaél
Aramburú Júnior, Jaime Sardá
Del Fabbro, Massimo
المصدر
العدد
المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-8، 8ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2018-04-11
دولة النشر
مصر
عدد الصفحات
8
التخصصات الرئيسية
الملخص EN
Objectives.
The present study aims to compare the drilling protocol effect on osseointegration event in three commercially available titanium dental implants with different drill protocol using a rabbit tibia model.
Materials and Methods.
Three different drilling sequences were compared as follows: drilling sequence using a single unique drill of 4.2 mm conical implant (Group 1), drilling sequence using 3 consecutive cylindrical drills for a 4.1 mm cylindrical implant (Group 2), and drilling sequence using 3 consecutive conical drills for a 4.3 mm conical implant (Group 3).
For each group, 18 drilling procedures and implant placements were performed, totalizing 54 commercially available titanium dental implants.
The samples were removed 6 weeks after implantation.
Resonance frequency analyses (RFA) were performed immediately after the implantation, and at 6 weeks removal torque test (RTt) and histological analysis were performed.
Results.
The RFA measured showed statistical difference between the groups in time 1 and no significant statistical differences in time 2 (p>0.05).
In the RTt no significant difference was found between the 3 groups tested.
Histomorphometric analysis showed no significant difference between groups in the bone-to-implant contact% (p>0.05).
Conclusion.
In the present preclinical study, osteotomy using a single bur did not show differences regarding the proposed and evaluated tests parameters for assessing the peri-implant behavior.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Gehrke, S. A.& Bettach, Raphaél& Aramburú Júnior, Jaime Sardá& Prados-Frutos, Juan Carlos& Del Fabbro, Massimo& Shibli, Jamil Awad. 2018. Peri-Implant Bone Behavior after Single Drill versus Multiple Sequence for Osteotomy Drill. BioMed Research International،Vol. 2018, no. 2018, pp.1-8.
https://search.emarefa.net/detail/BIM-1130005
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Gehrke, S. A.…[et al.]. Peri-Implant Bone Behavior after Single Drill versus Multiple Sequence for Osteotomy Drill. BioMed Research International No. 2018 (2018), pp.1-8.
https://search.emarefa.net/detail/BIM-1130005
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Gehrke, S. A.& Bettach, Raphaél& Aramburú Júnior, Jaime Sardá& Prados-Frutos, Juan Carlos& Del Fabbro, Massimo& Shibli, Jamil Awad. Peri-Implant Bone Behavior after Single Drill versus Multiple Sequence for Osteotomy Drill. BioMed Research International. 2018. Vol. 2018, no. 2018, pp.1-8.
https://search.emarefa.net/detail/BIM-1130005
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1130005
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر