![](/images/graphics-bg.png)
Is Subcutaneous Route an Alternative to Intravenous Route for Mouse Contrast-Enhanced Magnetic Resonance Imaging at 1.5 T?
المؤلفون المشاركون
Constantinesco, André
Kremer, Stéphane
Dillenseger, Jean-Philippe
Goetz, Christian
Sayeh, Amira
Zorn, Pierre-Emmanuel
Rémond, Yves
Aubertin-Kirch, Gaëlle
Choquet, Philippe
العدد
المجلد 2019، العدد 2019 (31 ديسمبر/كانون الأول 2019)، ص ص. 1-11، 11ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2019-06-13
دولة النشر
مصر
عدد الصفحات
11
التخصصات الرئيسية
الملخص EN
The present work compares intravenous (IV) and subcutaneous (SC) routes for contrast-enhanced MRI (CE-MRI) in mice.
For that purpose, we selected two contrast media used in clinical practice.
MRI acquisitions were performed at 1.5 T on five adult mice (Swiss, 41 g +/- 3 g).
On each animal, four acquisitions were achieved with IV and SC administration of either Gd-DOTA or MS-325 (1 acquisition per week).
For each route, 0.1 mL of NaCl and 0.1 mL of contrast agent were injected.
For each acquisition, 200 T1-weighted images were acquired in a 2 h 34 min time lapse.
For each route and contrast medium, dynamic contrast enhancement (DCE) curves were obtained.
Time-to-peak (TTP), uptake, and washout constant-time values and contrast-to-noise ratio (CNR) were extracted.
IV route TTP value was 4.9 min with Gd-DOTA and 5.4 min with MS-325.
SC route TTP was 43.3 min with Gd-DOTA and 45.0 min with MS-325.
Despite slower uptake constant-time, we show that SC is a potentially valuable alternative to the IV route in mouse preclinical CE-MRI.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Dillenseger, Jean-Philippe& Goetz, Christian& Sayeh, Amira& Zorn, Pierre-Emmanuel& Kremer, Stéphane& Rémond, Yves…[et al.]. 2019. Is Subcutaneous Route an Alternative to Intravenous Route for Mouse Contrast-Enhanced Magnetic Resonance Imaging at 1.5 T?. Vol. 2019, no. 2019, pp.1-11.
https://search.emarefa.net/detail/BIM-1130810
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Dillenseger, Jean-Philippe…[et al.]. Is Subcutaneous Route an Alternative to Intravenous Route for Mouse Contrast-Enhanced Magnetic Resonance Imaging at 1.5 T?. No. 2019 (2019), pp.1-11.
https://search.emarefa.net/detail/BIM-1130810
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Dillenseger, Jean-Philippe& Goetz, Christian& Sayeh, Amira& Zorn, Pierre-Emmanuel& Kremer, Stéphane& Rémond, Yves…[et al.]. Is Subcutaneous Route an Alternative to Intravenous Route for Mouse Contrast-Enhanced Magnetic Resonance Imaging at 1.5 T?. . 2019. Vol. 2019, no. 2019, pp.1-11.
https://search.emarefa.net/detail/BIM-1130810
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1130810
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)