Radiosynthesis and Preliminary Biological Evaluation of 18F-Fluoropropionyl-Chlorotoxin as a Potential PET Tracer for Glioma Imaging

المؤلفون المشاركون

Tang, Ganghua
Gao, Siyuan
Zhao, Jing
Wang, Yu-liang
Li, Xin-bei
Liu, Shao-yu
Song, Yu-kun
Wang, Jing-yan
Xiong, Ying
Ma, Hui
Jiang, Li
Yang, Zhi-yun
Chu, Jian-ping

المصدر

Contrast Media & Molecular Imaging

العدد

المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-9، 9ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2018-12-20

دولة النشر

مصر

عدد الصفحات

9

التخصصات الرئيسية

الأمراض
الطب البشري

الملخص EN

Purposes.

Chlorotoxin can specifically bind to matrix metalloproteinase 2 (MMP-2), which are overexpressed in the glioma.

In this work, radiosynthesis of [18F]-fluoropropionyl-chlorotoxin ([18F]-FP-chlorotoxin) as a novel PET tracer was investigated, and biodistribution in vivo and PET imaging were performed in the C6 glioma model.

Procedures.

[18F]-FP-chlorotoxin was prepared from the reaction of chlorotoxin with [18F]-NFB (4-nitrophenyl 2-[18F]-fluoropropionate), which was synthesized from multistep reactions.

Biodistribution was determined in 20 normal Kunming mice.

Small-animal PET imaging with [18F]-FP-chlorotoxin was performed on the same rats bearing orthotopic C6 glioma at different time points (60 min, 90 min, and 120 min) after injection and compared with 2-deoxy-2-[18F] fluoro-D-glucose ([18F]-FDG).

Results.

[18F]-FP-Chlorotoxin was successfully synthesized in the radiochemical yield of 41% and the radiochemical purity of more than 98%.

Among all the organs, the brain had the lowest and stable uptake of [18F]-FP-chlorotoxin, while the kidney showed the highest uptake.

Compared with [18F]-FDG, a low uptake of [18F]-FP-chlorotoxin was detected in normal brain parenchyma and a high accumulation of [18F]-FP-chlorotoxin was found in the gliomas tissue.

The glioma to normal brain uptake ratio of [18F]-FP-chlorotoxin was higher than that of [18F]-FDG.

Furthermore, the uptake of [18F]-FP-chlorotoxin at 90 min after injection was better than that at 60 min after injection.

Conclusions.

Compared with [18F]-FDG, [18F]-FP-chlorotoxin has a low and stable uptake in normal brain parenchyma.

[18F]-FP-Chlorotoxin seems to be a potential PET tracer with a good performance in diagnosis of the glioma.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Zhao, Jing& Wang, Yu-liang& Li, Xin-bei& Gao, Siyuan& Liu, Shao-yu& Song, Yu-kun…[et al.]. 2018. Radiosynthesis and Preliminary Biological Evaluation of 18F-Fluoropropionyl-Chlorotoxin as a Potential PET Tracer for Glioma Imaging. Contrast Media & Molecular Imaging،Vol. 2018, no. 2018, pp.1-9.
https://search.emarefa.net/detail/BIM-1131586

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Zhao, Jing…[et al.]. Radiosynthesis and Preliminary Biological Evaluation of 18F-Fluoropropionyl-Chlorotoxin as a Potential PET Tracer for Glioma Imaging. Contrast Media & Molecular Imaging No. 2018 (2018), pp.1-9.
https://search.emarefa.net/detail/BIM-1131586

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Zhao, Jing& Wang, Yu-liang& Li, Xin-bei& Gao, Siyuan& Liu, Shao-yu& Song, Yu-kun…[et al.]. Radiosynthesis and Preliminary Biological Evaluation of 18F-Fluoropropionyl-Chlorotoxin as a Potential PET Tracer for Glioma Imaging. Contrast Media & Molecular Imaging. 2018. Vol. 2018, no. 2018, pp.1-9.
https://search.emarefa.net/detail/BIM-1131586

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1131586