Left Atrial Ball-Shaped Thrombus with Concomitant Biatrial Appendage Thrombi in a Patient with Prior Mitral Valve Replacement
المؤلفون المشاركون
Akamatsu, Kanako
Ito, Takahide
Sakane, Kazushi
Kanzaki, Yumiko
Sohmiya, Koichi
Hoshiga, Masaaki
المصدر
العدد
المجلد 2019، العدد 2019 (31 ديسمبر/كانون الأول 2019)، ص ص. 1-4، 4ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2019-04-16
دولة النشر
مصر
عدد الصفحات
4
التخصصات الرئيسية
الملخص EN
We reported a 67-year-old woman in whom large atrial thrombi were found by chance during discontinuation of therapeutic anticoagulation.
The patient, with a history of mitral valve replacement surgery, had stopped anticoagulation for months because of intractable gastrointestinal bleeding, during which she was found to have 3 large thrombi in the atria on transesophageal echocardiography: left atrial free-floating ball-shaped thrombus, left atrial appendage thrombus, and right atrial appendage thrombus.
One month following diagnosis, she still had the free-floating thrombus despite adequate anticoagulation.
Free-floating ball-shaped thrombus is a rare finding observed on echocardiography in patients with mitral valve disease and an even rarer finding in case of appendage thrombi coexisting.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Akamatsu, Kanako& Ito, Takahide& Sakane, Kazushi& Kanzaki, Yumiko& Sohmiya, Koichi& Hoshiga, Masaaki. 2019. Left Atrial Ball-Shaped Thrombus with Concomitant Biatrial Appendage Thrombi in a Patient with Prior Mitral Valve Replacement. Case Reports in Cardiology،Vol. 2019, no. 2019, pp.1-4.
https://search.emarefa.net/detail/BIM-1133878
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Akamatsu, Kanako…[et al.]. Left Atrial Ball-Shaped Thrombus with Concomitant Biatrial Appendage Thrombi in a Patient with Prior Mitral Valve Replacement. Case Reports in Cardiology No. 2019 (2019), pp.1-4.
https://search.emarefa.net/detail/BIM-1133878
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Akamatsu, Kanako& Ito, Takahide& Sakane, Kazushi& Kanzaki, Yumiko& Sohmiya, Koichi& Hoshiga, Masaaki. Left Atrial Ball-Shaped Thrombus with Concomitant Biatrial Appendage Thrombi in a Patient with Prior Mitral Valve Replacement. Case Reports in Cardiology. 2019. Vol. 2019, no. 2019, pp.1-4.
https://search.emarefa.net/detail/BIM-1133878
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1133878
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر