Periaortic Abscess following DeBakey Type-1 Aortic Dissection Repair with Dacron Graft—Early Diagnosis and Management
المؤلفون المشاركون
Jacob, Aasems
Raj, Rishi
Unnikrishnan, Dileep
Ashish, Kumar
Prakash, Amulya
Shah, Ajay
المصدر
العدد
المجلد 2019، العدد 2019 (31 ديسمبر/كانون الأول 2019)، ص ص. 1-5، 5ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2019-05-08
دولة النشر
مصر
عدد الصفحات
5
التخصصات الرئيسية
الملخص EN
A 71-year-old male with history of DeBakey type-1 aortic dissection and repair with dacron graft three months prior to presentation was brought to the emergency room with complaints of high-grade fevers, chills, and shortness of breath.
Chest X-ray revealed right lower lobe infiltrates and widened superior mediastinum.
A follow-up CT chest with contrast showed fluid collection around the aortic graft.
He was started on intravenous broad-spectrum antibiotics, and a TEE was done for further evaluation of periaortic fluid collection which showed findings to suggest periaortic abscess.
The patient underwent surgical drainage of the abscess and was found to have an abscess around the surgical aortic graft which was drained followed by two weeks of antibiotic treatment.
The patient was discharged to a rehabilitation facility and remained asymptomatic at three-month follow-up appointment.
Type-1 aortic dissection is a medical emergency requiring acute surgical intervention, and despite significant advancements in diagnosis and management, the immediate and long-term complications remain high leading to increased risk of mortality.
Our patient developed spontaneous periaortic abscess three months postoperatively requiring intensive antibiotic therapy along with surgical drainage.
Our case emphasizes the importance of early diagnosis and management of late complications of periaortic abscess in patients with aortic dissection repair.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Raj, Rishi& Unnikrishnan, Dileep& Jacob, Aasems& Ashish, Kumar& Prakash, Amulya& Shah, Ajay. 2019. Periaortic Abscess following DeBakey Type-1 Aortic Dissection Repair with Dacron Graft—Early Diagnosis and Management. Case Reports in Cardiology،Vol. 2019, no. 2019, pp.1-5.
https://search.emarefa.net/detail/BIM-1133905
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Raj, Rishi…[et al.]. Periaortic Abscess following DeBakey Type-1 Aortic Dissection Repair with Dacron Graft—Early Diagnosis and Management. Case Reports in Cardiology No. 2019 (2019), pp.1-5.
https://search.emarefa.net/detail/BIM-1133905
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Raj, Rishi& Unnikrishnan, Dileep& Jacob, Aasems& Ashish, Kumar& Prakash, Amulya& Shah, Ajay. Periaortic Abscess following DeBakey Type-1 Aortic Dissection Repair with Dacron Graft—Early Diagnosis and Management. Case Reports in Cardiology. 2019. Vol. 2019, no. 2019, pp.1-5.
https://search.emarefa.net/detail/BIM-1133905
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1133905
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر