A Rare Central Venous Catheter Malposition in a 10-Year-Old Girl

المؤلفون المشاركون

Movafegh, Ali
Saliminia, Alireza
Atef-Yekta, Reza
Azimaraghi, Omid

المصدر

Case Reports in Anesthesiology

العدد

المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-3، 3ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2018-01-23

دولة النشر

مصر

عدد الصفحات

3

التخصصات الرئيسية

الطب البشري

الملخص EN

Central venous catheters (CVCs) are placed in operating rooms worldwide via different approaches.

Like any other medical procedure, CVC placement can cause a variety of complications.

We report the case of an unexpected malposition of a catheter in the right internal jugular vein, where it looped back on itself during placement and went upward into the right internal jugular vein.

CVC line placement should always be viewed as a procedure that could become complicated, even in the hands of the most experienced operators.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Movafegh, Ali& Saliminia, Alireza& Atef-Yekta, Reza& Azimaraghi, Omid. 2018. A Rare Central Venous Catheter Malposition in a 10-Year-Old Girl. Case Reports in Anesthesiology،Vol. 2018, no. 2018, pp.1-3.
https://search.emarefa.net/detail/BIM-1137016

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Movafegh, Ali…[et al.]. A Rare Central Venous Catheter Malposition in a 10-Year-Old Girl. Case Reports in Anesthesiology No. 2018 (2018), pp.1-3.
https://search.emarefa.net/detail/BIM-1137016

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Movafegh, Ali& Saliminia, Alireza& Atef-Yekta, Reza& Azimaraghi, Omid. A Rare Central Venous Catheter Malposition in a 10-Year-Old Girl. Case Reports in Anesthesiology. 2018. Vol. 2018, no. 2018, pp.1-3.
https://search.emarefa.net/detail/BIM-1137016

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1137016