![](/images/graphics-bg.png)
Pressure Differences from Clear Aligner Movements Assessed by Pressure Sensors
المؤلفون المشاركون
Kim, Woong-Chul
Kim, Hae-Young
Kim, Ji-Hwan
Son, Ho-jung
Lee, Kyeong-ho
Sim, Ji-young
المصدر
العدد
المجلد 2020، العدد 2020 (31 ديسمبر/كانون الأول 2020)، ص ص. 1-4، 4ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2020-03-12
دولة النشر
مصر
عدد الصفحات
4
التخصصات الرئيسية
الملخص EN
Objectives.
In this study, a clear aligner was moved at intervals of 0.25 mm and pressure variations were assessed using a sensor.
Methods.
The model used for producing the clear aligner was created using a 3-dimensional printer.
A clear, circular thermoplastic of 0.75 mm thickness was used for making the clear aligner using the vacuum forming method.
A pressure sensor was used to assess the pressure in the device, and the variation in the sheet pressure was statistically analyzed tooth movement using the clear aligner, moving at an interval of 0.25 mm, is recommended.
Results.
The results of pressure sensor assessment showed that the pressure of the devices with 0.25 mm and 1.00 mm movements was identical to that of the device with 0 mm movement.
In other words, the pressure sensor could not distinguish the pressure of devices that moved 0.25 mm and 1.00 mm.
Conclusions.
This experiment demonstrated that a movement of more than 0.50 mm is needed to apply the appropriate pressures needed for orthodontics in a clear polymer sheet.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Son, Ho-jung& Lee, Kyeong-ho& Sim, Ji-young& Kim, Hae-Young& Kim, Ji-Hwan& Kim, Woong-Chul. 2020. Pressure Differences from Clear Aligner Movements Assessed by Pressure Sensors. BioMed Research International،Vol. 2020, no. 2020, pp.1-4.
https://search.emarefa.net/detail/BIM-1137422
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Son, Ho-jung…[et al.]. Pressure Differences from Clear Aligner Movements Assessed by Pressure Sensors. BioMed Research International No. 2020 (2020), pp.1-4.
https://search.emarefa.net/detail/BIM-1137422
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Son, Ho-jung& Lee, Kyeong-ho& Sim, Ji-young& Kim, Hae-Young& Kim, Ji-Hwan& Kim, Woong-Chul. Pressure Differences from Clear Aligner Movements Assessed by Pressure Sensors. BioMed Research International. 2020. Vol. 2020, no. 2020, pp.1-4.
https://search.emarefa.net/detail/BIM-1137422
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1137422
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)